Records from 2010 to 2026. Most recent: inspection, 30 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
30 January 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304125
30 January 2026
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304155
30 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8112988
17 January 2025
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8065045
4 March 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7881958
22 March 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7655006
24 January 2023
Drydock Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7620766
21 March 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7417438
5 April 2021
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7169018
5 April 2021
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7169029
14 August 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7032710
17 July 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7008698
8 March 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6638878
8 February 2019
Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6622660
4 May 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405553
30 May 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6161952
5 May 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6139669
14 April 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6124672
27 June 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5921072
28 April 2016
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5864490
5 September 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5717980
14 May 2014
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4852468
18 February 2011
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3945560
6 December 2010
Construction Oversight · Initial Certification · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3904953
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2026
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. MI observed marking missing for location of children life jackets. Vessel shall reinstall legible letters; letters and numbers must be at least 50 millimeters (2 inches) high.
46CFR185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2026
Resolved 25 February 2026
Resolution: photos provided, stickers replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 January 2026
Resolved
Each ring life buoy must be market with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. MI observed retroreflective material corroded around ring life buoy. Vessel operator shall replace with Type II retroreflective material approved in accordance with 46 CFR 164.018
46CFR185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2026
Resolved 25 February 2026
Resolution: retro replaced, pictures provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 April 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. MI observed visual indicators not operating.
46 CFR 182.530(3)(c)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2025
Resolution: Vessel owner replaced broken lamp
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 March 2024
Resolved
Each vessel certificated to operate on a limited coastwise route within 3 miles of land in warm water must have onboard an FCC Type accepted category 1 406 MHz EPIRB, installed to automatically float free and activate, and not be required to carry survival craft. Inspector observed the EPIRB activated and unable to secure signal. Secure EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2024
Resolution: Received email with new EPIRB installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2024
Resolved
Placards containing instructions for the donning and use of the lifejackets aboard the vessel must be posted in inconspicuous places that are regularly accessible and visible to the crew and passengers. Inspector observed the sign faded and worn. Replace
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 April 2024
Resolution: Received photo of new placard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2023
Resolved
The fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The pull handle for the port fuel shutoff valve broke off of the mounting, which has dry rotted, preventing the cable from fully pulling the shutoff valve closed. Manual closure from outside engine compartment shall be fully made prior to vessel returning to operation with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2023
Resolved 19 April 2023
Resolution: Video call with operator to witness closure of valve via remote pull.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2023
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The marking for the child size life jackets was half painted over. The marking for child size life jackets needs to be relabeled and separation between adult and child size lifejackets has to be created prior to vessel operation with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2023
Resolved 18 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2021
Resolved
Ring life buoy was in an unservicable condition with a missing plug.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2021
Resolved 15 April 2021
Resolution: A new approve Life Buoy was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2021
Resolved
6 adult life jackets were found with worn and deteriorated retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2021
Resolved 15 April 2021
Resolution: New approved life jackets were installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 April 2021
Resolved
FCC Station License was expired 47 CFR 80.13
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 27 April 2021
Resolution: Vessel owner provided a valid FCC Station License.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 April 2021
Resolved
The rotating shaft from the engine to the parasail spool has no guard over it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 26 April 2021
Resolution: A guard was put in place covering the rotating shaft.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2021
Resolved
Life jacket stowage compartment was not clearly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2021
Resolved 15 April 2021
Resolution: Life jacket stowage compartment has been clearly marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2020
Resolved
Each portable fire extinguisher must be in good working order and general condition. 40-B:C located at operating station found with gauged needle below limits. Replace or service portable extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 14 August 2020
Resolution: Vessel operator provided photographic evidence of fully serviced fire extinguisher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2020
Resolved
Crew members are required to be tested for alcohol after serious marine incidents. Found alcohol testing strips expired. Replace alcohol testing strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 14 August 2020
Resolution: Vessel operator provided photographic evidence of new alcohol testing strips with valid expiration dates.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017
Resolved
Need proper chart for operating area. IAW 46 CFR 185.420
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 30 May 2017
Resolution: Chart on board.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 May 2017
Resolved
Bilge light needs to come on when the bilge is operating. IAW 46 CFR 182.530
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 30 May 2017
Resolution: Light repaired and working.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 May 2016
Resolved
EAP supervisor training completion is required. Complete EAP training and provide documentation IAW 46 CFR 16.401 for all crewmembers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 27 June 2016
Resolution: Provided proof of completion of EAP Supervisor Training.
Lifesaving › Lifejacket/PFD (Type IV) › Storage
Issued 18 February 2011
Resolved
Properly mount ring life bouy & floating water light.
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 11 May 2011
Resolution: Properly mounted ring life bouy & floating water light.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 February 2011
Resolved
Provide protective guards for forward engine belt & chain drive on winch
Action required: 705 - Other - as specified
Due 18 March 2011
Resolved 11 May 2011
Resolution: Provided protective guards for forward engine belt & chain drive on winch
Documentation › Certificates/Documents › FCC SSL
Issued 6 December 2010
Resolved
Provide FCC SSL, Radio Safety & MROP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2011
Navigation › Piloting/Steering › Marine Charts
Issued 6 December 2010
Resolved
Provide Nav Pubs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2011
Communications › Radio Communications › EPIRB
Issued 6 December 2010
Resolved
Provide NOAA registration for the EPIRB, and mount (the EPIRB).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2011
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 December 2010
Resolved
Provide batteries for portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2011
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 December 2010
Resolved
Provide battery for water light and mount (the light).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 December 2010
Resolved
Conduct Machinery Operational test and New to Zone inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 December 2010
Resolved
Conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2010