MAURY USCG vessel records
← All vessels

STAR DALMATIA

STAR DALMATIA is a 2010 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in November 2024, along with 6 deficiencies and 1 operational control.

Records from 2016 to 2024. Most recent: operational control imposed, 5 November 2024.

Built
2010
Last inspected
5 November 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9548835
1104519
Flag
MARSHALL ISLANDS
Maury page id
psix-1104519

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2016–2024)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it51593 - Dead Weight, Metric Ton
64136 - Displacement, Metric Ton
33601 - Convention (Subpart B), Gross Ton
16737 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 16

5 November 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8029947
9 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7977919
23 July 2024 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7964821
20 December 2022 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7611405
15 August 2022 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7534279
15 July 2020 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7002761
18 October 2019 ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6830732
9 October 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6831333
20 December 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6592573
6 December 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6592941
20 August 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6515753
19 December 2017 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6323052
19 October 2017 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6287140
13 March 2017 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6101213
14 December 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6057805
7 November 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6032679

Deficiency record · 6

Fire Fighting › Remote Fuel Shutoff › General
Issued 19 December 2017 Resolved
FIRE PROTECTION SYSTEMS AND FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED READY FOR USE. A PORTION OF THE CONTROL AIRLINE TO THE EMERGENCY FUEL SHUTOFFS TO THE GENERATORS AND THE MAIN ENGINE WERE CROPPED AND REPLACED WITH TRANSLUECENT FLEX HOSE SECURED BY HOSE CLAMPS. CODE: 0750 CITE: 74SOLAS(14) CHII-2 / 14.1.1 ACTION: 17AC
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 22 December 2017
Resolved 21 December 2017
Resolution: All emergency fuel shut off piping was inspected, repaired, and tested by Class.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 December 2017 Resolved
THE FIXED FIRE DETECTION AND FIRE ALARM SYSTEM REQUIRED IN 4.1.1 SHALL BE SO DESIGNED AND THE DETECTORS SO POSITIONED AS TO DETECT RAPIDLY THE ONSET OF FIRE IN ANY PART OF THOSE SPACES AND UNDER ANY NORMAL CONDITIONS OF OPERATION OF THE MACHINERY. FIRE DETECTOR OVER #3 GENERATOR WAS TAPED TO PREVENT PROPER OPERATION OF SENSOR. CODE: 0915 CITE: 74SOLAS(14) CHII-2 / 7.4.2 ACTION: 17ABC
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2017
Resolved 20 December 2017
Resolution: Fire detector was tested and tape was removed.
Stability › Watertight Integrity › General
Issued 19 December 2017 Resolved
THE ARRANGEMENT OF THE BILGE AND BALLAST PUMPING SYSTEM SHALL BE SUCH AS TO PREVENT THE POSSIBILITY OF WATER PASSING FROM THE SEAS INOT THE CARGO AND MACHINERY SPACE. PSCO OBSERVED TWO PLUGS WRAPPED WITH FIBERGLASS CLOTH AROUND THE BALLAST STARINER JUST FORWARD OF THE SEACHEST WHICH PRESENTS A MAJOR FLODDING RISK. CODE:1499 CITE: 74SOLAS(14) CH II-1 / 35.1.2.4 ACTION: 17ABC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 March 2018
Resolved 20 August 2018
Resolution: RECEIVED, REVIEWED AND ACCEPTED CLASS REPORT.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 December 2017 Resolved
THE MACHINERY ASSOCIATED PIPING SYSTEM AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE SALT WATER COOLING PUMP'S MECHANICAL SEAL HAD FAILED. CODE: 1499 CITE: 74SOLAS(14) CH II-1 / 26.1 ACTION:17ABC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2017
Resolved 20 December 2017
Resolution: Mechanical seal was replaced using spare parts onboard and tested with no leaks.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 19 December 2017 Resolved
THE FIRE FIGHTERS OUTFITS OR SETS OF PERSONAL EQUIPMENT SHALL BE KEPT READY FOR USE; FIRE-FIGHTERS OUTFIT SHALL CONSIST OF PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. ONE OF THE REQUIRED FIRE-FIGHTERS OUTFIT CONTAINED RIPS AND TEARS. CODE: 0735 CITE:74SOLAS(14)CH. II-2 / 10.10.3.1 FSS CODE 3.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 December 2017
Resolved 20 December 2017
Resolution: Outfit was replaced with new suit, verified by MI.
Engineering › Pressure Vessel › Piping
Issued 7 November 2016 Resolved
1499-The machinery boilers and other pressure vessels, shall be of a design and construction adequate for the service for which they are intended. The number one air compressor has a cracked cylinder line. 74 SOLAS(14) II-I/26.1-50ac
Action required: 705 - Other - as specified
Due 7 December 2016
Resolved 14 December 2016
Resolution: Cleared deficiency with proper class report.