Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it108612 - Convention (Subpart B), Net Ton 162180 - Convention (Subpart B), Gross Ton 298778 - Dead Weight, Metric Ton 347054 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
1 inspection, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 1
6 December 2023Deficiency Check · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7828081
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 6 December 2023Resolved
The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. O2 analyzer was unable to produce less than 16% oxygen, at the time of inspection sample filter found empty, dry and with the gasket o-ring free inside.
74SOLAS(09) II-2/4.5.5.1.1
FSS Code 15.2.2.1.2.5
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Reinspected after class attendance and found sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 December 2023Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. ESD trip alarm is not operable in CC for any cargo oil pumps. "Common Trip" was initiated multiple times without external input. ESD trip alarms are unreliable.
74SOLAS(09) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Reinspected after class attendance and found sat.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 6 December 2023Resolved
The system shall be capable of delivering inert gas to the cargo tanks at a rate of at least 125% of maximum rate of discharge. Main IGS blower discharge side valve was not actuated without crew manipulation.
74SOLAS(09) II-2/4.5.5.1.1
FSS Code 15.2.2.1.2.4
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2023
Resolution: Reinspected after class attendance and found sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 December 2023Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. Cargo oil pump #2 sprayed cargo in the pump room after crew increased RPM's at a very high rate.
74SOLAS(09)1/11(a)
15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 7 December 2023
Resolution: Class attended vessel and inspected pump after COP ESD tests.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 6 December 2023Resolved
A system for the continuous monitoring of the concentration of hydrocarbon gases shall be fitted. Crew tried multiple times to initiate flow fault alarms in the cargo pump room but could not produce alarm in CCR. After tightening fittings, alarms were found operational.
74SOLAS(09) II-2/4.5.10.1.3
10c
Action required: 10 - Deficiency Rectified
Resolved 6 December 2023
Resolution: Crew tightened fitting and retested.