MAURY USCG vessel records Sign in
← All vessels

ECOFUTURE

ECOFUTURE is a 2009 tank ship. The Coast Guard has recorded 21 inspections since 2014, most recently in January 2026, along with 5 deficiencies and 6 operational controls.

Records from 2014 to 2026. Most recent: inspection, 16 January 2026.

Built
2009
Last inspected
16 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9486180 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1104695
Flag
LIBERIA
—
Maury page id
psix-1104695

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (2014–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11948 - Convention (Subpart B), Gross Ton
5180 - Convention (Subpart B), Net Ton
17055 - Dead Weight, Metric Ton
22629 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

16 January 2026 Administrative Inspection · PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8297435
7 August 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8204375
15 February 2025 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8080056
13 February 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8068872
1 March 2024 ISPS Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7872550
14 January 2024 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7849279
5 January 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7845491
2 June 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7466506
2 March 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7404853
27 February 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7402864
22 February 2022 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7399862
26 December 2021 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7372250
24 December 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7372248
21 December 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7364502
14 December 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7370336
13 December 2021 VRP Review
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7367202
24 November 2021 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7356991
8 August 2015 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5209376
1 August 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4943508
6 June 2014 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4881340
4 June 2014 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4879606

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2025 Resolved
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED MULTIPLE ELECTRICAL HAZARDS IN MACHINERY SPACES, INCLUDING EXPOSED WIRING BY MAIN ENGINE LUBE OIL AUTO FILTER, CAMERA BY THE OWS, LIGHT FIXTURE ABOVE REFRIGERATION UNIT, AND THE BREAKER FOR THE EMERGENCY DISTRIBUTION PANEL INSIDE THE EMERGENCY GENERATOR ROOM. ALSO OBSERVED NO NON-CONDUCTIVE MATS BY MULTIPLE SWITCHBOARDS AND CONTROL PANELS IN THE ENGINE ROOM. 74 SOLAS (04) II-1/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2025
Resolution: Class report attesting to safety repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 13 February 2025 Resolved
OIL FILTERING EQUIPMENT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED. THE SYSTEM SHALL ALSO BE PROVIDED WITH ARRANGEMENTS TO INDICATE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. PSCO OBSERVED INOPERABLE 15 PPM ALARMS. MARPOL ANNEX 1/14.7
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 March 2025
Resolution: Class report attesting to repair of alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 December 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed jacket water leak on number three cylinder of number three service generator. 74SOLAS(14)II-I/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2021
Resolution: Received, reviewed and accepted Class report attesting to the permanenet repair to the jacket water leak.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 December 2021 Resolved
In a ship in which fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons onboard and shall at least comply with the following provisions. Safe and efficient means of ascertaining the amount of oil fuel tank shall be provided. PSCO observed cover removed from high level alarm exposing disconnected wires. 74SOLAS(14)II-2/4.2.2.3.5
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 December 2021
Resolution: Received, reviewed and accepted Class report attesting to the alarm sensor being reinstalled as original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 December 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. On 13SEP2021 while inbound in Mississippi River main engine shutdown/slowdown alarm and oil pump changeover were activated due to low lube oil pressure. 74SOLAS(14)II-I/26.1
Action required: 10 - Deficiency Rectified
Due 21 December 2021
Resolved 21 December 2021
Resolution: Received, reviewed and accepted Class report attesting to the proper operation of Main Diesel Engine.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.