MAURY USCG vessel records
← All vessels

AMOY DREAM

AMOY DREAM is a 2010 freight ship. The Coast Guard has recorded 4 inspections since 2021, most recently in January 2024, along with 15 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 2021 to 2024. Most recent: inspection, 9 January 2024.

Built
2010
Last inspected
9 January 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 January 2024
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9583615
1104759
Flag
HONG KONG
Maury page id
psix-1104759

Documentation record

Tonnage as PSIX records it33044 - Convention (Subpart B), Gross Ton
33044 - Regulatory (Subpart C or D), Gross Ton
19231 - Convention (Subpart B), Net Ton
19231 - Regulatory (Subpart C or D), Net Ton
67681 - Displacement, Ton
56873 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

9 January 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7847056
10 January 2022 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7377916
8 December 2021 PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7364011
29 November 2021 PSC A · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7354295

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 8 December 2021 Resolved
07122 - Plans and booklets shall be kept up to date. Any alterations thereto shall be recorded as soon as practicable. Storage of the international shore connection does not match the location indicated on the Fire Control Plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 10 January 2022
Resolution: SEC NOLA PSC Arrivals Branch received a class report & proper documentation satisfying the requirements
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 8 December 2021 Resolved
The connection shall be kept... with four bolts of 16mm diameter and 50 mm in length, four 16mm nuts and eight washers. The fire control plan indicates two complete sets international shore connection sets, the vessel has only one complete set.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2022
Resolved 10 January 2022
Resolution: SEC NOLA PSC Arrivals Branch received a class report & proper documentation satisfying the requirements
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 8 December 2021 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by regulation II-1/42 or II-1/43 as appropriate. Port and Starboard side embarkation lights were both inoperable.
Action required: 10 - Deficiency Rectified
Due 8 December 2021
Resolved 8 December 2021
Resolution: The onboard electrician was able to replace the lighting bulbs while PSCO were still conducting inspection. Embarkation lights were energized and found to be operating correctly.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 November 2021 Resolved
Chief Engineer exhibted an overall lack of familiarity with the SMS prodcedures. previus month's Maintenance plan not competed. Emergency generator, main engine, steam system, and fire detection were found in various states of disrepair. these deficiencies indicate that the ship and/or company are not meeting the SMS requirements. An External Audit is Required.
Action required: 30 - Ship detained
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel to ensure SMS compliance.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 November 2021 Resolved
Each emergency generator set must be equipped with a second source of energy for starting. PSCO observed the second means of starting to be inoperable.
Action required: 30 - Ship detained
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class report and attended vessel to witness satisfactory start of the secondary means of the emregency generator.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 29 November 2021 Resolved
Connections within the fuel supply and spill lines shall be constructed having regard to thier ability and to prevent pressurized oil fuel leaks while in sevice and after maintenance. PSCO observed an active leak dripping off of the high pressure lines of the emergency generator.
Action required: 30 - Ship detained
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel, fuel leak not active.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2021 Resolved
In a ship in which fuel is used, the arrangements, for the storage, distribution and utilization of the fuel oil shall be such as to ensure the safety of the ship and persons onboard. PSCO observed an active fuel leak on the number one cylinder of the main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel. Crew has secured leak on the number one cylinder.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 November 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustable materials or flammable liquids; means shall be provided to control leaks of flammable liquids. PSCO observed excessive amounts of used oil in the engine room bilge, creating a fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel. Crew has cleaned up bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 November 2021 Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. PSCO observed the top rails on the starboard side of the vessel at cargo bay 1 and 3 and the middle rail at cargo bay 2 are cracked, presenting a potential safety hazards to the crew.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel. Crew has welded cracked rails.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 November 2021 Resolved
The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration. Vessel could not produce appropriate equipment to test the flame/heat detectors onbaord.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel to ensure testing equipement for the flame/heat detectors was onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 29 November 2021 Resolved
Every Steam Pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to withstand the maximum working stresses to which it may be subjected. PSCO observed an active steam leak coming from a valve on the steam line next to the heat exchanger.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 November 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel, valve was repaired and steam secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 November 2021 No resolution recorded
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and constructed adequate for the service for which they are intended. PSCO observed active jacket water leak on the number two cylinder of the main egnine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 November 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present requlations. PSCO observed an active water leak and multible gauges broken on the heat exchanger.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021
Resolved 3 December 2021
Resolution: Reviewed class audit and attended vessel, crew has addressed water leak and replaced broken gauges.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 29 November 2021 No resolution recorded
An immersion suit shall be constructed with waterproof materials such that; it can be unpacked and donned without assistance within 2 minutes. Immersion suit in boatswain hole could not be zipped up, preventing it from being donned.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2021 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 November 2021 Resolved
Each NOA must contain all of the information items specified in table 160.206. PSCO was questioning the captain regarding past ports and found NOA was not filled out with the correct previous five port calls.
Action required: 10 - Deficiency Rectified
Due 29 November 2021
Resolved 29 November 2021
Resolution: Captain was instructed on how to properly fill out an NOA

Ownership record