Records from 2024 to 2026. Most recent: inspection, 27 May 2026.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 May 2026
Resolved
AIS SHALL PROVIDE AUTOMATICALLY TO APPROPRIATELY EQUIPPED SHORE STATIONS, OTHER SHIPS AND AIRCRAFT INFORMATION, INCLUDING THE SHIP'S POSITION AND OTHER SAFETY-RELATED INFORMATION. PILOT OF THE VESSEL HAS REPORTED AN INACCURATE POSITION READING FROM THE VESSEL'S AIS.
74 SOLAS (20) V/19.5.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onborad. PSCO observed severe leak on jacket water piping on #1 cylinder head.
74SOLAS(20) I/ 11(a)
17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 May 2026
Resolution: Repairs approved by Class were made to the water piping jacket.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2026
Resolved
Prevent the ignition of combustible material or flammable liquids, means shall be provided to control leaks of flammable liquid. PSCO observed 02 devices on fuel gauges preventing them from operating as intended
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2026
Resolution: The devices were removed from the fuel gauges
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2026
Resolved
"Ignition sources shall be seperated from combustible materials." PSCO observed combustible materials in multiple spaces within engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 8 May 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2026
Resolved
"Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power." PSCO observed 11 emergency lights not functioning at superstructure, muster stations, and on main deck in multiple locations.
Action required: 10 - Deficiency Rectified
Resolved 6 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 May 2026
Resolved
EQUIPMENT AND ARRANGEMENTS FOR PILOT TRANSFER SHALL COMPLY WITH THE REQUIREMENT OF THIS REGULATION, AND DUE REGARD SHALL BE PAID TO STANDARDS ADOPTED BY THE ORGANIZATION. PSCO OBSERVED SECURING ROPES NOT MEETING THE STANDARDS ADOPTED BY THE ORGANIZATIONS RESOLUTION A.1045(27).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 March 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementing of the ISM Code. An external audit report satisfying to the OCMI must be submitted prior to clearance of this deficiency. 74SOLAS(20)Ix13.1, ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 March 2025
Resolution: External audit report provided was sufficient to attending PSCO at time of deficiency check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2025
Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such way that the accumulation of liquids is detected at normal angles of trim and heel... PSCO observed that the forwards port and STBD engine room bilge alarms were inoperable since 19DEC24. Additionally, a soft patch was found on a raw water pipe next to the inoperable STBD forward bilge alarm. 74SOLAS(04)II-1/ 48.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 March 2025
Resolution: Piping temporatily repaired. Attending BV surveyor issued a Condition Of Class for permanent repair to be completed by 19APR2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 3 March 2025
Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such way that the accumulation of liquids is detected at normal angles of trim and heel... PSCO observed that the level has been operating in an unmanned machinery space status without operable bilge alarms since 19DEC24. 74SOLAS(04)II-1/48.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 March 2025
Resolution: DPU#12 repaired. Attending PSCO verified operation of all 03 E/R high-water bilge alarms. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 January 2025
Resolved
The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. PSCO observed no appropriate flame detector tester.
74SOLAS(09) II-2/ 7.3.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 January 2025
Resolved 6 March 2025
Resolution: PSC team observed proper operation 06MAR25
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 January 2025
Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stored... additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch. PSCO observed no immersion suits located at the bridge watch station.
74 SOLAS(20) III.32.3.3 15ac
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2025
Resolution: PSC Team verified all required equipment on bridge 06Mar25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. PSCO observed no appropriate flame detector tester.
74SOLAS(09) II-2/ 7.3.2 15ac
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2025
Resolution: PSC Team observed proper testing. 06Mar25
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The machinery, boilers and other pressure vessels associated piping system and fittings shall be of a design and construction adequate for the serve of which they are intended. PSCO observed an unauthorized soft patch on the sea water overboard pipe.
74SOLAS(04)II-1/ 26.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 April 2025
Resolution: Rectified with Class Report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping system and fittings shall be of a design and construction adequate for the service of which they are intended. PSCO observed leaking from the LT coolers 1 and 2.
74SOLAS(04) II-1/ 26.1 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 21 April 2025
Resolution: Rectified with Class Report
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 January 2025
Resolved
Satisfactory means for safe passage required by regulation 25-1 (in the form of guard rails, lifelines, gangways or underdeck passages, etc.) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and any other spaces used in the essential operation of the ship. PSCO observed protective guard rail missing around STBD and Port anchor hawse pipes.
66ICLL (Prot 88) Reg. 25.4 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 6 March 2025
Resolution: PSC Team observed installed in proper location 06Mar25
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed the STBD forward deck light on cargo hold 1 was damaged leaving exposed electrical wiring.
74SOLAS(04) II-1/40.1.3 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 6 March 2025
Resolution: PSC Team examined operation of lighting 06Mar25
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed exposed start button covers on the motor controller for the No. 1 and 2 boiler H.F.O transfer pumps.
74SOLAS(04) II-1/ 40.1.3 50ac
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 6 March 2025
Resolution: Rectified and observed by PSC Team 06MAR25
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 January 2025
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed permanently affixed hold back hook on the self closing A- class door to the Fire Control Room/ Ships Office.
74SOLAS(09) II-2/ 9.4.2.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 March 2025
Resolution: Hold back was removed from the wall prior to end of exam.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2024
Resolved
The purpose of thisregulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed oil leak on #3 service generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 November 2024
Resolved
An alarm system shall be provided indicating any falt requiring attention. PSCO's observed faulty low oil alarm on #2, #3, #4 service generator.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2024
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2024
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to with stand the maximum working stresses to which it may be subjected. PSCO observed steam leak in piping located in the overhead of the purifier room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 November 2024
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 November 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of the deficiencies noted above provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted prior to the clearance of this deficiency.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a broken lock on door to CO2.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2024