← All vessels
ODYSSEUS
Freight Ship · General Dry Cargo Ship class · Built 2000s · USCG Southeast District (CGD-SE) · Other hulls named ODYSSEUS
ODYSSEUS is a 2006 freight ship. The Coast Guard has recorded 10 inspections since 2012, most recently in May 2026, along with 23 deficiencies and 2 operational controls.
Records from 2012 to 2026. Most recent: inspection, 27 May 2026.
- Built
- 2006
- Last inspected
- 27 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 23 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9315824 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8KC9
1104776
Flag
LIBERIA
—
Maury page id
psix-1104776
Inspections, by type
Years with a record
4 calendar years (2012–2026)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28592 - Convention (Subpart B), Gross Ton
14769 - Convention (Subpart B), Net Ton
39383 - Dead Weight, Ton
14769 - Convention (Subpart B), Net Ton
39383 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
27 May 2026
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8381522
6 May 2026
PSC B · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8360866
21 April 2025
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8116507
10 March 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8090861
3 March 2025
PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8087111
16 January 2025
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8064733
14 January 2025
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8062965
27 November 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8039505
21 November 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8038222
24 July 2012
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4388870
Deficiency record · 23
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 8 May 2026
Resolved
AIS SHALL PROVIDE AUTOMATICALLY TO APPROPRIATELY EQUIPPED SHORE STATIONS, OTHER SHIPS AND AIRCRAFT INFORMATION, INCLUDING THE SHIP'S POSITION AND OTHER SAFETY-RELATED INFORMATION. PILOT OF THE VESSEL HAS REPORTED AN INACCURATE POSITION READING FROM THE VESSEL'S AIS.
74 SOLAS (20) V/19.5.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2026
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onborad. PSCO observed severe leak on jacket water piping on #1 cylinder head.
74SOLAS(20) I/ 11(a)
17AC
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2026
Resolved
Prevent the ignition of combustible material or flammable liquids, means shall be provided to control leaks of flammable liquid. PSCO observed 02 devices on fuel gauges preventing them from operating as intended
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2026
Resolved
"Ignition sources shall be seperated from combustible materials." PSCO observed combustible materials in multiple spaces within engine room.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2026
Resolved
"Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of power." PSCO observed 11 emergency lights not functioning at superstructure, muster stations, and on main deck in multiple locations.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 May 2026
Resolved
EQUIPMENT AND ARRANGEMENTS FOR PILOT TRANSFER SHALL COMPLY WITH THE REQUIREMENT OF THIS REGULATION, AND DUE REGARD SHALL BE PAID TO STANDARDS ADOPTED BY THE ORGANIZATION. PSCO OBSERVED SECURING ROPES NOT MEETING THE STANDARDS ADOPTED BY THE ORGANIZATIONS RESOLUTION A.1045(27).
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 3 March 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The operational nature of the deficiencies noted below provide objective evidence of a serious failure of the implementing of the ISM Code. An external audit report satisfying to the OCMI must be submitted prior to clearance of this deficiency. 74SOLAS(20)Ix13.1, ISM Code 10.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2025
Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such way that the accumulation of liquids is detected at normal angles of trim and heel... PSCO observed that the forwards port and STBD engine room bilge alarms were inoperable since 19DEC24. Additionally, a soft patch was found on a raw water pipe next to the inoperable STBD forward bilge alarm. 74SOLAS(04)II-1/ 48.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 3 March 2025
Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such way that the accumulation of liquids is detected at normal angles of trim and heel... PSCO observed that the level has been operating in an unmanned machinery space status without operable bilge alarms since 19DEC24. 74SOLAS(04)II-1/48.1
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 January 2025
Resolved
The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. PSCO observed no appropriate flame detector tester.
74SOLAS(09) II-2/ 7.3.2
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 14 January 2025
Resolved
If a ship has any watch or work stations which are located remotely from the place or places where immersion suits are normally stored... additional immersion suits of an appropriate size shall be provided at these locations for the number of persons normally on watch. PSCO observed no immersion suits located at the bridge watch station.
74 SOLAS(20) III.32.3.3 15ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The function of the fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature. PSCO observed no appropriate flame detector tester.
74SOLAS(09) II-2/ 7.3.2 15ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The machinery, boilers and other pressure vessels associated piping system and fittings shall be of a design and construction adequate for the serve of which they are intended. PSCO observed an unauthorized soft patch on the sea water overboard pipe.
74SOLAS(04)II-1/ 26.1 50ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2025
Resolved
The machinery, boilers and other pressure vessels, associated piping system and fittings shall be of a design and construction adequate for the service of which they are intended. PSCO observed leaking from the LT coolers 1 and 2.
74SOLAS(04) II-1/ 26.1 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 January 2025
Resolved
Satisfactory means for safe passage required by regulation 25-1 (in the form of guard rails, lifelines, gangways or underdeck passages, etc.) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and any other spaces used in the essential operation of the ship. PSCO observed protective guard rail missing around STBD and Port anchor hawse pipes.
66ICLL (Prot 88) Reg. 25.4 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed the STBD forward deck light on cargo hold 1 was damaged leaving exposed electrical wiring.
74SOLAS(04) II-1/40.1.3 50ac
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2025
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed exposed start button covers on the motor controller for the No. 1 and 2 boiler H.F.O transfer pumps.
74SOLAS(04) II-1/ 40.1.3 50ac
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 January 2025
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. PSCO observed permanently affixed hold back hook on the self closing A- class door to the Fire Control Room/ Ships Office.
74SOLAS(09) II-2/ 9.4.2.2 10c
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 November 2024
Resolved
The purpose of thisregulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed oil leak on #3 service generator.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 November 2024
Resolved
An alarm system shall be provided indicating any falt requiring attention. PSCO's observed faulty low oil alarm on #2, #3, #4 service generator.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 November 2024
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed and installed as to with stand the maximum working stresses to which it may be subjected. PSCO observed steam leak in piping located in the overhead of the purifier room.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 22 November 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and operational nature of the deficiencies noted above provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted prior to the clearance of this deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 November 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed a broken lock on door to CO2.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National