Records from 2015 to 2026. Most recent: inspection, 24 July 2026.
Inspection history · 21
24 July 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8445515
20 January 2025
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8086933
9 December 2024
PSC B · COC-TVE Renew · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8045037
24 December 2023
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7842276
18 December 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7839990
29 July 2023
COC-TVE Annual · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7754994
29 June 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7726507
21 June 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7719774
13 February 2023
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7638186
15 May 2022
Administrative Inspection · COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7450805
5 May 2021
COC-TVE Annual
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7186297
31 January 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7133589
12 November 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7094063
13 September 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7057192
19 May 2020
PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6954599
6 November 2018
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6575608
13 September 2018
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6534959
17 October 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5744430
18 September 2015
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5725014
17 September 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5721217
11 August 2015
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5204967
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 December 2024
Resolved
46CFR39.2001(6)(j)- EACH VESSEL VAPOR CONNECTION FLANGE FACE MUST HAVE A PERMANANT STUD PROJECTING OUTWARD THAT HAS A 12.7 mm DIAMETER AND IS AT LEAST 25.4 mm LONG. IT MUST BE LOCATED AT THE TOP OF THE FLANGE FACE, MIDWAY BETWEEN BOLT HOLES, AND IN LINE WITH THE BOLT HOLE PATTERN. PSCO OBSERVED NO PERMANANT STUD ON VAPOR CONNECTION FLANGE FACE ON THE PORT AND STARBOARD SIDE OF THE VESSEL.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 11 December 2024
Resolution: Vessel added permanant stud to port and starbord side.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 24 December 2023
Resolved
ON EACH TANKER OF 10,000 GROSS TONS OR MORE THAT IS SUBJECT TO 46 U.S.C. 3708, THE DUAL RADAR SYSTEM REQUIRED BY THIS PART MUST HAVE A SHORT RANGE CAPABILITY AND A LONG RANGE CAPABILITY; AND EACH RADAR MUST HAVE TRUE NORTH FEATURES CONSISTING OF A DISPLAY THAT IS STABLIZED IN AZIMUTH. THE SUBJECT VESSEL CURRENTLY HAS A NON-FUNCTIONING S-BAND RADAR.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 March 2024
Resolved 14 December 2024
Resolution: Provided satisfactory technician report.
Engineering › Fuel Oil Service System › Pump
Issued 11 August 2015
Resolved
During exam PSCO found a minor leak on the #4 fuel pump. 10c.
Due 11 August 2015
Resolved 11 August 2015
Resolution: Engineers corrected on the spot.