SOPHIA KOSAN is a 2008 tank ship. The Coast Guard has recorded 11 inspections since 2016, most recently in April 2022, along with 4 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2016 to 2022. Most recent: inspection, 12 April 2022.

Built
2008
Last inspected
12 April 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 April 2022
…with no type recorded2
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9374557
1104800
Flag
SINGAPORE
Maury page id
psix-1104800

Documentation record

Tonnage as PSIX records it9175 - Convention (Subpart B), Gross Ton
2753 - Convention (Subpart B), Net Ton
15328 - Displacement, Metric Ton
10343 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

12 April 2022 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7422308
14 January 2021 COC-GAS Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7119397
24 September 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7064002
24 September 2020 Deficiency Check · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7064167
3 February 2020 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7083099
19 January 2020 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6890029
21 March 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6646511
10 November 2018 ISPS II Exam · COC-GAS Renew · Ballast Water Examination · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6577536
9 November 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6578307
2 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5867217
9 March 2016 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5826122

Deficiency record · 4

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 24 September 2020 Resolved
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and auxiliary steering gear to the satisfaction of the administration. It was reported to Sector New Orleans that the vessel had experienced steering gear irregularity. Demonstrate proper operation and readiness of the steering gear system. SOLAS 74(am) II-1/29
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 September 2020
Resolution: Received a tech report from Mackay Marine & class report from BV. Tech boarded the vessel for repair. Tested the steering gear system in all modes and pumps and was found in good working order.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 November 2018 Resolved
The rings lines and letters shall be painted in white or yellow on a dark ground. They shall be permanently marked on the sides of the ship. On the STBD side, the deck line is not painted contrasting colors and the load line is not permanently marked. 66 ICLL I/7 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 December 2018
Resolved 13 November 2018
Resolution: Recieved email with photos of the painted load line.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other cargo/timber/deck/construction
Issued 10 November 2018 Resolved
Air lock doors should be self closing. Exterior airlock door was not self closing. 74SOLAS14 VII/13.1 IGC 3.6.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2018
Resolution: Recieved email varifying the renewal of the self-clsoing device for the exterior airlock door.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 9 March 2016 Resolved
Condition of the ship shall be maintained to conform with the provisions of the present regulations. PSCO observed the ventilation opening for the emergency generator room did not have a means of manual closure as indicated locally by posted IMO placard and on the ships fire control plan.
Condition: Improper Installation
Due 8 April 2016
Resolved 2 May 2016
Resolution: SEC HOUSTON-GALVESTON received proper documentation (02 photos) attestinf to the rectification of the deficiency.