MAURY USCG vessel records
← All vessels

ATLANTAS

ATLANTAS is a 2010 tank ship. The Coast Guard has recorded 8 inspections since 2018, most recently in June 2023, along with 3 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 2018 to 2023. Most recent: inspection, 8 June 2023.

Built
2010
Last inspected
8 June 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 June 2023
Operational controls 1 with no removal date recorded
Years with a record 5 calendar years (2018–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9389899
1104904
Flag
LIBERIA
Maury page id
psix-1104904

Documentation record

Tonnage as PSIX records it162198 - Regulatory (Subpart C or D), Gross Ton
112192 - Regulatory (Subpart C or D), Net Ton
162198 - Convention (Subpart B), Gross Ton
112192 - Convention (Subpart B), Net Ton
321300 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 8

8 June 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7709906
18 October 2022 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7574138
14 October 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7577354
21 April 2021 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7174300
14 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6643307
7 March 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6633401
6 January 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6606104
30 January 2018 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6342122

Deficiency record · 3

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 October 2022 Resolved
The deck line is a horizontal line 300mm in length and 25mm in breadth. It shall be marked amidships on each side of the ship. Deck line is not marked on either side of the ship. It has been painted over.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2022
Resolved 28 October 2022
Resolution: Received pictures of the repainted deck line.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 21 April 2021 Resolved
A system for continuous monitoring of the concentration of hydrocarbon gases in the cargo pump room shall be fitted. Pump room gas detection system observed to have a flow fault. 74 SOLAS (09 Cons.) II-2/4.5.10.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2022
Resolution: Received documentation stating the fixed gas sampling pump was replaced so there is no flow fault.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 April 2021 Resolved
The high level (and tank overfill) alarms required by paragraph (a) of this section must be identified with the legend "High-Level Alarm" (and "TANK OVERFILL ALARM") in black letters at least 50.8 mm (2 in) high on a white background. Alarms observed to be labeled illegibly in gray. 46 CFR 39.2007 (c) and (d)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2022
Resolution: Received report stating that the labeling was refreshed with black paint.