CHANG HANG KAI TUO is a 2009 tank ship. The Coast Guard has recorded 5 inspections since 2010, most recently in September 2025, along with 3 deficiencies and 1 operational control.
Records from 2010 to 2025. Most recent: inspection, 13 September 2025.
The 5 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for CHANG HANG KAI TUO, retrieved 18 September 2026. mauryrecords.com/v/psix-1105018.html
Documentation record
Tonnage as PSIX records it29578 - Convention (Subpart B), Gross Ton 12471 - Convention (Subpart B), Net Ton 29578 - Simplified, Gross Ton 45790 - Dead Weight, Metric Ton 57719 - Displacement, Metric Ton 12471 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
13 September 2025Deficiency Check · PSC B · COC-TVE Renew · Administrative Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8225708
1 June 2023COC-TVE Renew · PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7701275
12 April 2016ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 5852830
12 April 2016Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5852897
28 December 2010MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3928752
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 13 September 2025Resolved
The inert gas system referred to in paragraph 5.5.3.1 shall be designed, constructed and tested in accordance with the FSS Code. Testing switch and plunger for low level alarm on deck water seal, found broken and fitted with unapproved repair and testing method.
74 SOLAS (2004 Cons.) II-2/4.5.5.3.2 - 17 a
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2025
Resolved 15 September 2025
Resolution: Received CCS remote survey class report. See class report attached to the document section of this activity.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 September 2025Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electricla requirements of a classification society. Numerous bonding straps on the tank washing lines throughout the cargo deck found broken or wasted.
74 SOLAS (2004 Conss) II-1/3-1 - 17 a
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2025
Resolved 15 September 2025
Resolution: Received CCS remote survey class report. See class report attached to the document section of this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 September 2025Resolved
Doors fitted inboundary bulkheads or machninery spaces of catagory A shall be reasonably gas tight and self-closing. Class A door "109-2" found not gas tight or self-closing due to deteriorated latch.
74 SOLAS (2004 Cons.) II-2/9.4.2.1 - 17 a.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 September 2025
Resolved 15 September 2025
Resolution: Received CCS remote survey class report. See class report attached to the document section of this activity.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.