Records from 2010 to 2020. Most recent: inspection, 22 September 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
22 September 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7063126
25 April 2019
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6683376
22 May 2018
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6441970
8 June 2017
Annual Inspection · In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6169713
13 June 2016
Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5906844
17 March 2014
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4886153
12 July 2012
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4376539
19 December 2011
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4207206
14 December 2010
Initial Certification · Simplified Stability Test · Initial Construction-Excluding Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3910633
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 May 2018
Resolved
Expired meds in first aid kit. Replace with current meds.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 31 May 2018
Resolved 31 May 2018
Resolution: New meds provided to expire 10/2019.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 June 2017
Resolved
Retro-relfective tape was damaged, needed full replacement.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 9 June 2017
Resolution: Corrected on the spot, to satisfaction of USCG MI.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 June 2017
Resolved
Lifeline clip was inoperable and stuck in the open position, needed full replacement.
Action required: 705 - Other - as specified
Due 9 November 2017
Resolved 9 June 2017
Resolution: Vessel installed new clip, to satisfaction of USCG MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 June 2017
Resolved
Battery was expired, full replacement needed.
Due 9 June 2017
Resolved 9 June 2017
Resolution: Replaced battery in kind, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 June 2017
Resolved
07 lifejackets needed reconditioning with jim buoy material to cover cuts in foam.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 9 June 2017
Resolution: Each lifejacket identified was reconditioned, all sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 9 June 2017
Resolved
01 adult lifejacket waiste clip, stuck in the open position unable to be secured.
Due 9 June 2017
Resolved 9 June 2017
Resolution: Vessel replaced waist strap and clip in kind, all sat.
Engineering › Bilge Water Management System › Pump
Issued 19 December 2011
Resolved
Hand bilge pump not functional.
Action required: 705 - Other - as specified
Due 19 December 2011
Resolved 19 December 2011
Resolution: Cleared on site. New pump was placed on board.
Documentation › Markings/Placards › Lifejacket Placard
Issued 19 December 2011
Resolved
PFD donning placard not posted.
Action required: 705 - Other - as specified
Due 19 December 2011
Resolved 19 December 2011
Resolution: Cleared on site. New placard was posted.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 December 2011
Resolved
Emergency instructions not posted.
Action required: 705 - Other - as specified
Due 19 December 2011
Resolved 19 December 2011
Resolution: Cleared on site. New placard was posted.