MAURY USCG vessel records
← All vessels

NEW ENTERPRISE

NEW ENTERPRISE is a tank ship. The Coast Guard has recorded 1 inspection in 2016, along with 1 deficiency — 1 with no resolution recorded —.

Records in 2016. Most recent: inspection, 12 August 2016.

Built
Not recorded
Last inspected
12 August 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9405227
1105052
Flag
HONG KONG
Maury page id
psix-1105052

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it160218 - Regulatory (Subpart C or D), Gross Ton
160218 - Convention (Subpart B), Gross Ton
103527 - Regulatory (Subpart C or D), Net Ton
103527 - Convention (Subpart B), Net Ton
310444 - Dead Weight, Ton
351414 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

12 August 2016 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5974275

Deficiency record · 1

Electrical › Electrical Distribution System (service) › Wiring
Issued 14 August 2016 No resolution recorded
All 6 Thermal Couples on #1 and #2 Ballast Pumps and 2 Thermal Couples on the COW pump are installed improperly. Such installation may create ignition source in a space where flammable vapors may be present during normal operations. Vessel shall secure #1 and #2 ballast pumps and COW pump during cargo operations.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.