MAURY USCG vessel records
← All vessels

ATLANTIC ACTION II

ATLANTIC ACTION II is a 2010 freight ship. The Coast Guard has recorded 29 inspections since 2016, most recently in May 2026, along with 7 deficiencies and 6 operational controls.

Records from 2016 to 2026. Most recent: inspection, 30 May 2026.

Built
2010
Last inspected
30 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9509633
V7A5843
1105081
Flag
MARSHALL ISLANDS
Maury page id
psix-1105081

Inspections, by type

…with no type recorded8
Years with a record 10 calendar years (2016–2026)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it22863 - Convention (Subpart B), Gross Ton
10602 - Convention (Subpart B), Net Ton
33128 - Dead Weight, Metric Ton
43436 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 29

30 May 2026 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8384058
9 April 2026 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8345337
3 April 2026 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8341626
5 November 2025 PSC C · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8264441
15 May 2025 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8136379
21 March 2025 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8097389
6 March 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8089164
15 November 2023 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7827556
3 October 2023 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7802371
21 March 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7654274
22 August 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7540270
19 August 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7540854
8 July 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7501132
24 February 2022 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7401214
20 May 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7201658
26 April 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7182796
3 February 2020 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6901460
3 February 2020 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6901471
21 August 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6790652
19 August 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6787762
26 March 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6649554
11 January 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6611839
20 August 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6517402
7 June 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6436886
2 April 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6383156
14 March 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6099449
2 August 2016 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5956761
16 May 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5879382
8 March 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5829206

Deficiency record · 7

09 - Working and Living Conditions › 092 - Working Conditions › Stowage of cargo
Issued 21 March 2025 Resolved
Cargo, cargo units and cargo transport units carried on or under deck shall be so loaded, stowed, and secured as to prevent as far as practical, throughout the voyage, damage or hazard to the ship and person on board. PSCO were informed that the ship had damaged containers in cargo holds 3, 4, and 5. Vessel has hired salvers to remove damaged containers. Hold five has been emptied and preliminary inspected by class. Cargo holds 3 and 4 still have damaged cargo and unkown damage to the holds. 74SOLAS(24)VI/5.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 April 2025
Resolution: Received, Reviewed and Accepted class report and Flag clearance. Attached.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2022 Resolved
The following requirements shall govern application of the tables: Table 9.5 and 9.6 shall apply respectively to the bulkheads and decks separating adjacent spaces. PSCOs identified compromised fire boundary in A-60 fire escape trunk in the engine room. There was a 2x3 foot cut out where the insulation and interior bulkhead were removed. Crew informed marine inspector that insulation and interior bulkhead were removed when ballast water treatment system was installed in 2018. 74 SOLAS (04) II-2/9.2.3.3.2.1
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 April 2022
Resolved 3 March 2022
Resolution: Received class survey statng that PSC deficiency has bee rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 April 2021 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. Rescue boat was unable to start
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 April 2021
Resolved 26 April 2021
Resolution: Crew was able to start the rescue boat prior to the team disembarking, opp test sat, issued 10c.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 April 2021 Resolved
In additon to the requirements contained elsewhere in the present regulations, ships shall be maintained in compliance with the electrical requirements of a classification society. Vessel found with six inoperable emergency lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2021
Resolved 3 May 2021
Resolution: 03MAY2021-Sector Delaware Bay recieved survey statement from class for the repairs on the emergency lighting light bulbs, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 August 2019 Resolved
03107: ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS THAT ARE WEATHERTIGHT WHEN CLOSE. [name withheld] THROUGH MULTIPLE WEATHERTIGHT DOORS ON THE SUPERSTRUCTURES NOT CREATING A WEATHERTIGHT SEAL. ICLL II/12.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2019
Resolution: RECIEVED CLASS SURVEY STATING THE DOORS HAVE BEEN REPAIRED AND RECTIFIED. SURVEY STATEMENT ADDED TO DOCUMENTS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 August 2019 Resolved
07124: INSPECTIONS SHOULD BE CARRIED OUT BY THE CREW TO ENSURE THAT THE INDICATED WEEKLY, MONTHLY, QUARTERLY, ANNUAL, TWO YEAR, FIVE YEAR, AND TEN YEAR ACTIONS ARE TAKEN. INSPECTIONS FOR THE VESSELS FLAME DETECTORS ARE NOT BEING CONDUCTED. MSC CIR. 1432 SOLAS(14) II-2/14.2.2.1
Action required: 10 - Deficiency Rectified
Resolved 19 August 2019
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 March 2017 Resolved
0715 - Detection - Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed one smoke detector in the engine room workshop that was fitted with a cover preventing it from operating properly as designed. SOLAS 74 (2014) II-2/14.1 10C
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: Cover was removed from smoke detector and was tested for operational readiness in presence of PSCO.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.