2011
Last inspected
31 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 31 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2011–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1105094
Flag
UNITED STATES
Maury page id
psix-1105094

Documentation record

Registered dimensions (L × B × D)150.0 ft × 54.0 ft × 13.0 ft
Registered tonnagegross 884 / net 884
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRES PALACIOS MARINE LP · PALACIOS, TX, UNITED STATES · built 2011
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it884 - Simplified, Gross Ton
884 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STONE FUELER Towing Vessel · MISLE 334501 · 3 June 2024 · activity 7925928STONE FUELER Towing Vessel · MISLE 334501 · 7 March 2023 · activity 7647190LAURA S Towing Vessel · MISLE 151768 · 7 November 2012 · activity 4480712

Inspection history · 17

31 July 2026 COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8392672
3 June 2024 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7925928
7 March 2023 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7647190
13 October 2021 MTSA Verification · Internal Structural Exam · Drydock Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7332125
31 May 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6445072
17 August 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6271114
17 August 2016 COI Inspection · Internal Structural Exam · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5974977
13 June 2015 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5154340
11 June 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5165618
21 October 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5009452
31 July 2014 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4940023
26 July 2013 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4665419
7 November 2012 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4480712
3 July 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4366203
1 December 2011 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4199197
18 August 2011 Initial Construction-Excluding Oversight
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4125022
18 August 2011 Initial Certification · MTSA Verification · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4125044

Deficiency record · 5

Electrical › Electric Supply System (service) › Cable
Issued 18 August 2016 Resolved
Properly support light fixture wire under storage area cover IAW 46 CFR 111.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Electrical › Electric Supply System (service) › Cable
Issued 18 August 2016 Resolved
Make cannon plug for stern light watertight and install junction box plug in open port for junction box.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: Junction box removed and plug installed.
Engineering › Fuel Oil Service System › Hose
Issued 18 August 2016 Resolved
Replace all dry-cracking fuel oil supply and return hoses for both cargo pump engines and hydraulic resivoir tank return hose.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 25 August 2016
Resolution: All hose replace with new ones.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 18 August 2011 Resolved
Install emergency shutdowns for both cargo pump engines at the midpoint of the vessel or 100 feet away. 46 CFR 32.50-35
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 22 August 2011
Resolution: Emergency stops relocated as required.
Engineering › Fuel Oil Service System › Hose
Issued 18 August 2011 Resolved
Remove all fuel hoses over 30" in length as required by 46 CFR 56.60-25(b)(4).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 22 August 2011
Resolution: Removed fuel hoses over 30" in length and installed hard piping.