MAURY USCG vessel records
← All vessels

ETHRA GOLD

ETHRA GOLD is a 2010 freight ship. The Coast Guard has recorded 6 inspections since 2021, most recently in June 2025, along with 2 deficiencies.

Records from 2021 to 2025. Most recent: inspection, 12 June 2025.

Built
2010
Last inspected
12 June 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 12 June 2025
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9548328
V7A6416
1105111
Flag
MARSHALL ISLANDS
Maury page id
psix-1105111

Documentation record

Tonnage as PSIX records it20865 - Convention (Subpart B), Gross Ton
11820 - Convention (Subpart B), Net Ton
32598 - Dead Weight, Metric Ton
41748 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

12 June 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8157760
29 January 2025 Administrative Inspection · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8071709
16 August 2024 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7982945
7 April 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7891176
9 May 2023 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7676965
19 July 2021 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7250418

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 June 2025 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNTTION OF COMBUSTBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET, MEANS SHALL BE POVIDED TO LIMIT THE ACCUMULATION OF FLAMMABLE VAPORS. PSCO OBSERVED SIGNIGICANT OLL ACCUMULATION UNDER ALL 3 PRIME MOVERS FOR THE SHIPS GENERATORS WITH RAGS COLLECTING OIL AND APPROXIMATELY ONE INCH OF STANDING OIL ON THE CYLINDER HEADS OF GENERATORS #1 AND #3. ADDITIONALLY A WATER BOTTLE WAS OBSERVED ON THE MAIN ENGINE COLLECTING OIL FROM A FUEL OIL DRAIN LINE. 74 SOLAS(09) II-2/4.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2025
Resolution: O-rings and fuel line fittings were replaced, re-tightening all fuel oil injection pumps, pipes, and fittings, leaks cleaned, and bottle removed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 June 2025 Resolved
THE FIRE RESISTANCE OF DOORS SSHALL BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED, THIS BEING DETERMINED IN ACCORDANCE WITH THE FIRE TEST PROCEDURES CODE. PSCO OBSERVED (04) "A" CLASS SELF-CLOSING DOORS NOT PROPERLY CLOSING OR LATCHING ADDITIONALLY, "A" CLASS SELF-CLOSING DOOR FOUND WITH HOLD BACK ON BRIDGE WATER CLOSET. IN TOTAL, (05) SELF-CLOSING DOORS WERE FOUND UNSATISFACTORY. 74 SOLAS(09) II-2/9.4.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2025
Resolution: Adjusted hinges, replaced hinges, and removed strand. Class also conducted training with crew.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.