Records from 2010 to 2011. Most recent: inspection, 4 January 2011.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Steering Gear System › Linkage
Issued 26 December 2010
Resolved
Steering pump inoperable. Couplings for hydraulic pump worn/broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 December 2010
Resolution: Temperary repair made to the steering pump.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 26 December 2010
Resolved
Fire doors not closing throughout main vertical egress.
Action required: 705 - Other - as specified
Resolved 28 December 2010
Resolution: Fire doors have been repaired
Engineering › Bilge Water Management System › Interface Detector
Issued 26 December 2010
No resolution recorded
Bilge alarms inoperable for port gear box and starboard bilge well.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 December 2010
No resolution recorded
Electrical shock protection mats missing in front of numerous electrical panels.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Fuel Oil Service System › Valve
Issued 26 December 2010
No resolution recorded
Emergency fuel shutoff cable inoperable to emergency diesel generator space.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 26 December 2010
No resolution recorded
Electrical hazard in engine control room. Saltwater intrusion throughout ceiling and vents.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Cargo Stowage › General
Issued 26 December 2010
No resolution recorded
Unsafe storage of oxygen and acetylene bottles on open deck and tied down.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 26 December 2010
No resolution recorded
Lagging missing or worn on numerous pipes for electrical generators and engine space.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (electric)
Issued 26 December 2010
No resolution recorded
Maintain secondary means of starting emergency diesel generator.
Condition: Improper/Lack of Maintenance