← All vessels
CLIPPER APOLLONIA
CLIPPER APOLLONIA is a 2010 freight ship. The Coast Guard has recorded 13 inspections since 2012, most recently in July 2024, along with 5 deficiencies and 4 operational controls.
Records from 2012 to 2024. Most recent: inspection, 20 July 2024.
- Built
- 2010
- Last inspected
- 20 July 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9527996 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2625
1105157
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1105157
Inspections, by type
…with no type recorded4
Years with a record
7 calendar years (2012–2024)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it20809 - Convention (Subpart B), Gross Ton
11689 - Convention (Subpart B), Net Ton
32740 - Dead Weight, Metric Ton
41748 - Displacement, Metric Ton
11689 - Convention (Subpart B), Net Ton
32740 - Dead Weight, Metric Ton
41748 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
20 July 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7962884
18 July 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7961002
16 July 2024
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7960314
18 January 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7382106
12 January 2022
Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7379220
17 April 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7177028
10 April 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7172406
9 June 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6964019
13 January 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6065691
29 March 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4825934
29 March 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4826544
24 March 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4821713
24 January 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4230700
Deficiency record · 5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 July 2024
Resolved
The machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected. The #2 AE has exhause leak.
74SOLAS(20) II-1 26.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 12 January 2022
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. The emergency source of electrical power shall be capable, having regard to starting currents and the transitory nature of certain loads, of supplying simultaneously at least the following services for the periods specified hereinafter, if they depend upon an electrical source for their operation. PSCO discovered that the emergency generator does not work as designed since the emergency bus bar does not connect to any other emergency systems. The emergency generator is incapable of providing power to required systems.
- 74SOLAS(20) II-1/43.2
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 January 2022
Resolved
The steering gear compartments shall be provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other nonslip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. There are no gratings or nonslip surfaces in the steering gear compartment.
- 74SOLAS(20) II-1/29.13.2
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 January 2022
Resolved
Emergency lighting must be provided at every muster and embarkation station and over the sides as required by regulations III/11.4 and III/16.7. PSCO observed 05 emergency lights that failed to illuminate.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 12 January 2022
Resolved
Each discharge overboard or disposal otherwise of bilge water which has accumulated in machinery spaces shall be fully recorded without delay in the oil record book part 1, so that all entries in the book appropriate to that operation are completed. The vessels OWS maximum throughput is 5.0 cubic meters/hour. Oil record book entry made on May 10, 2021 states that 12.2 cubic meters of bilge water was discharged over board through the OWS between 1957 UTC and 2130 UTC.
- MARPOL Annex I, Reg 17.4
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.