MAURY USCG vessel records
← All vessels

LOKI

LOKI is a 2008 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in January 2026, along with 11 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 22 January 2026.

Built
2008
Last inspected
22 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2829
1105180
Flag
UNITED STATES
Maury page id
psix-1105180

Documentation record

Tonnage as PSIX records it3 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

22 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8299903
17 December 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8277562
16 January 2025 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8059679
22 January 2024 In-Service Inspection · Internal Structural Exam · COI Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7847288
19 January 2023 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7624501
25 March 2022 Examination of Repairs · Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7418983
6 January 2022 Examination of Repairs · DAPI Audit · Internal Structural Exam · Drydock Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7376388
3 March 2021 Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7153013
23 June 2020 DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6984708
22 January 2020 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6893910
15 February 2019 Administrative Inspection · COI Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6626310
4 January 2018 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6593060
9 October 2017 Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293302
24 January 2017 Internal Structural Exam · DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6109088
28 January 2016 Drydock Exam · DAPI Audit · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5807682

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 May 2022 Resolved
Found fuel residue on fiberglass hull damage under STBD fuel tank. Must hydrotest fuel tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2022
Resolution: Installed two new aluminum fuel tanks.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 March 2022 Resolved
STBD hull had several cracks/holes from midships to stern on keel. Must cut back all cracks and de lamination for further inspection.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2022
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 March 2022 Resolved
Port hull had several cracks/holes from midships to stern on keel area. Must cut back all cracks and de lamination for further inspection
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 January 2022 Resolved
Annual service for portable fire extinguishers was not conducted. Must have extinguishers serviced IAW NFPA 10 or show proof of purchasing new extinguishers prior to carry passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2022
Resolution: Bought 2 new extinguishers.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 January 2022 Resolved
FCC Safety Certificate expired NOV 16th 2021. Must have VHF re certified and issued new FCC Safety Certifiecate 47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 February 2022
Resolved 2 February 2022
Resolution: New FCC certificate issued.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 March 2021 Resolved
All Captains for company do not have FCC operators permit as required if carrying more 6 passengers. Must take course and pass test to receive FCC operators permit in order to operate vessel. 47 CFR 80.159(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 20 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 March 2021 Resolved
Alcohol swabs expired Feb 20, 2020. Must have valid alcohol testing available for all employees involved in a marine casualty.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2021
Resolved 19 March 2021
Resolution: Owner/ Operator submitted evidence of restocking a dozen new alco swabs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 February 2019 Resolved
Life ring strobe lanyard clip is wasted and must be renewed.
Action required: 705 - Other - as specified
Due 20 February 2019
Resolved 16 February 2019
Resolution: New clip was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 February 2019 Resolved
Vessel is missing 2 orange smoke flares. Provide prior to any operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 February 2019
Resolution: 2 New flares were provided.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 24 January 2017 Resolved
Vessel registration is endorsed as recreational, Re-submit for commercial service.
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: New registration was provided with the correct endorsement.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 January 2017 Resolved
Vessel is missing portable flashlight at the operators station.
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 7 February 2017
Resolution: Portable lights were provided and mounted near the operators station.

Ownership record