GENCO NORMANDY
GENCO NORMANDY is a 2007 freight ship. The Coast Guard has recorded 19 inspections since 2011, most recently in March 2020, along with 13 deficiencies and 6 operational controls.
Records from 2011 to 2020. Most recent: inspection, 18 March 2020.
- Built
- 2007
- Last inspected
- 18 March 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9347877 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7IC7
1105219
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1105219
Inspections, by type
…with no type recorded7
Years with a record
4 calendar years (2011–2020)
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it53596 - Dead Weight, Metric Ton
63708 - Displacement, Metric Ton
31107 - Convention (Subpart B), Gross Ton
18361 - Convention (Subpart B), Net Ton
63708 - Displacement, Metric Ton
31107 - Convention (Subpart B), Gross Ton
18361 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
18 March 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6928568
12 March 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6925279
15 October 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6829048
5 October 2019
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6828686
30 September 2019
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6824892
27 September 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6822798
28 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6764347
27 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6769788
17 July 2019
Deficiency Check · NPV Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6752953
13 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6748634
11 July 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6745848
3 May 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6676502
14 February 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6625982
23 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6602210
22 December 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6601817
28 November 2018
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6588565
10 January 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6335480
23 September 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4148237
8 February 2011
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3937808
Deficiency record · 13
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 July 2019
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. WHILE LOWERING THE STARBAORD LIFEBOAT, IT WAS OBSERVED THAT THE REMOTE CONTROL / BRAKE RELEASE LINE HAD PREVIOUSLY BECAME UNBRAIDED/BROKE AND WAS SPLICED BACK TOGETER.
SOLAS 74 (2014 CONS) III/20.2
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 July 2019
Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. FIRE HOSE BOXES ON DECK WERE OBSERVED IN POOR CONDITION AND NOT ABLE TO BE OPENED OR CLOSED PROPERLY DUE TO BROKEN LATCHES. ADDITIONALLY, 02 FIRE HOSE BOXES WERE OBSERVED WITH THE FIRE HOSE MISSING AND THE FORWARD FIRE BOX MISSING THE NOZZLE.
SOLAS 74 (2004 CONS) II-2/14.2.1.2
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 17 July 2019
Resolved
TO ASSIST IN CASUALTY INVESTIGATIONS, SHIPS WHEN ENGAGED ON INTERNATIONAL VOYAGES, SUBJECT TO THE PROVISIONS 1.4 SHALL BE FITTED WITH A VOYAGE DATA RECORDER (VDR) AS FOLLOWS: SHIPS OTHER THAN PASSENGER SHIPS OF 3,000 GROSS TONNAGE AND UPWARDS CONSTRUCTED ON OR AFTER 1JULY2002.
VOYAGE DATE RECORDER (VDR)NOT CONNECTED TO THE ECDIS OR THE ECHO SOUNDER. WHEN THE ABOVE MENTION DEVICES ARE TURNED OFF NO VDR ALARM IS PRESENT.
SOLAS 74 (2014 CONS) V/20.1.4
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 July 2019
Resolved
PROVISIONS SHALL BE MADE TO FACILITATE CLEANING, INSPECTION AND MAINTENANCE OF MAIN PROPULSION AND AUXILLIARY MACINERY. EXCESSIVE COLLECTIONS OF FUEL OIL WERE OBSERVED AROUND THE MAIN ENGINE DUE TO LEAKING FUEL INJECTORS. POOLED OIL WAS OBSERVED IN PURIFIER ROOM AROUND PURIFIERS AND STORED IN A BUCKET. EXCESSIVE OIL WAS FOUND IN THE BILGE UNDERNEATH THE SHAFT SEAL.
SOLAS 74 (2004 CONS) II-1/26.7
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 17 July 2019
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY.
THE CREW LOWERED THE STARBOARD LIFEBOAT AND MANUEVERED IT IN THE WATE ON 24JUN2019. THEY IDENTIFIED THE REMOTE CONTROL/BRAKE RELEASE WIRE WAS BROKEN. THE CREW SPLICED THE WIRE BACK TOGETHER AND DID NOT REPORT TO COMPANY OR CLASS. ALSO, MULTIPLE FIRE BOXES ARE IN POOR CONDITION, UNABLE TO OPEN OR CLOSE PROPERLY OR ARE MISSING THE FIRE HOSE OR NOZZLE. THE 3/0, C/0, AND MASTER ALL REPORTED THE ITEMS IN GOOD CONDITION DURING THE MONTHLY LSA/FSS INSPECTIONS. THE EXCESSIVE OIL IN THE ENGINE ROOM IS DUE TO A LACK OF MAINTENANCE. THE CREW IDENTIFIED MULTIPLE MAINTENANCE ITEMS, BUT HAVE MADE NO ATTEMPT TO RECTIFY THE PROBLEMS. ON 20JUN2019, THE CREW IDENTIFIED M/E CYLINDER #1 PISTON RING IS BROKEN, BUT HAVE YET TO REPLACE IT. AN ISM AUDIT IS RECOMMENDED.
ISM CODE PART A 10.1 30ABC
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 July 2019
Resolved
COMPONENTS OF A DIESEL ENGINE FUEL SYSTEM SHALL BE DESIGNED CONSIDERING THE MAXIMUM PEAK PRESSURE WHICH WILL BE EXPERIENCED IN SERVICE, INCLUDING ANY HIGH PRESSURE PULSES WHICH ARE GENERATED AND TRANSMITTED BACK INTO THE FUEL SUPPLY AND SPILL LINES BY THE ACTION OF FUEL INJECTION PUMPS. CONNECTIONS WITHIN THE FUEL SUPPLY AND SPILL LINES SHALL BE CONSTRUCTED HAVING REGARD TO THERE ABILITY TO PREVENT PRESSURIZED OIL FUEL LEAKS WHILE IN SERVICE AND AFTER MAINTENANCE. POOLED OIL AROUND FUEL INJECTORS SHOW EVIDENCE FOR LEAKS.
SOLAS 74 (2004 CONS) II-2/ 4.2.2.5.4 17AC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 July 2019
Resolved
ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS OF STEEL OR OTHER EQUIVALENT MATERIAL, PERMANENTLY AND STRONGLY ATTACHED TO THE BULKHEAD, AND FRAMED, STIFFENED, AND FITTED SO THAT THE WHOLE STRUCTURE IS OF EQUIVALENT STRENGTH TO THE UNPIERCED BULKHEAD AND WEATHERTIGHT WHEN CLOSED.
THE STEERING GEAR EMERGENCY ESCAPE DOOR WAS FOUND TO NOT BE WEATHERTIGHT WHEN CLOSED. SUNLIGHT WAS VISIBLE THROUGH A GAP BETWEEN THE DOOR AND FRAME.
ICLL 66 12.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 July 2019
Resolved
SATISFACTORY MEANS SHALL BE PROVIDED FOR THE PROTECTION OF THE CREW IN GETTING TO AND FROM THEIR QUARTERS, MACHINERY SPACES, AND ALL OTHER PARTS USED IN THE NECESSARY WORK OF THE SHIP.
PORT SIDE AMIDSHIPS DECK RAILING WAS FOUND TO BE BROKEN.
ICLL 66/ 25.4 40AC
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 July 2019
Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIP TO THE SATISFACTION OF THE ADMINISTRATION.
PSCO OBSERVED LOAD LINE MISSING PAINT ON PORT SIDE.
ICLL 66/ 8 40AC
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 19 February 2019
Resolved
40ac
Machinery and fittings shall be of a design and construction adequate for the service for which they are intended.
#5 cargo tank (port FWD) cylinder and the #2 Cargo tank (aft STBD) cylinder are leaking excessive hydraulic oil on deck.
74 SOLAS (04)II-1/26.1
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 10 January 2018
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following funcitional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Port State Control found one hose between CO2 cylinders to be disconnected. 74 SOLAS (14) II-2/14.1.1
Navigation › Collision/Grounding Avoidance › Radar
Issued 10 January 2018
Resolved
All ships of 3,000 gross tonnage and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: a 3 GHz radar... to determine and display the range and bearing of other surface craft. The S-band (3GHz) radar was found to be malfunctioning. 74 SOLAS (14) V/19.2.7.1
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 8 February 2011
Resolved
Code 0725: Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Two Flexible hoses connecting to Co2 cylinders were found to be broken from fitting.
74 Solas (2009 consolidated edition) chapter II-2: Reg. 14.2.1.2 40(a)(c)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.