BLU TIDE is a 2011 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in January 2020, along with 3 deficiencies.

Records from 2016 to 2020. Most recent: inspection, 10 January 2020.

Built
2011
Last inspected
10 January 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 January 2020
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9576739
1105362
Flag
PANAMA
Maury page id
psix-1105362

Documentation record

Tonnage as PSIX records it23054 - Convention (Subpart B), Gross Ton
35916 - Dead Weight, Metric Ton
44715 - Displacement, Metric Ton
11349 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

10 January 2020 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6882111
9 January 2020 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6882170
23 January 2019 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6614234
23 December 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6600759
21 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6327619
16 December 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6321558
28 July 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5948466

Deficiency record · 3

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 December 2018 Resolved
14108:Except as specified in paragraph 3 of this regulation, any ship of 10000GT and above shall be fitted with Oil Filtering Equipment complying with paragraph 7 of this regulation: The 15ppm bilge alarm should record date, time, and alarm status. PSCO observed the oil content meter GMT date display of 19 October 2018 (current date 23DEC18) and previous ORB dates were dates that they were conducted. Last calibration of monitoring equipment showed GMT date correct. MARPOL Annex I 14.2 MEPEC.107(49) 50a,c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2019
Resolved 23 January 2019
Resolution: Received Class report stating that the equipment was operating properly and in accordance with regulations. See documents tab for attached Class Report.
Lifesaving › Inflatable Liferafts › Float Free
Issued 16 December 2017 Resolved
0628-Stowage of liferafts- Each life raft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of the LSA Code that each floats free and, if inflatable, inflates automatically when the ship sinks. The PSCO observed the painter attached directly to the liferaft cradle preventing the proper operation of the float free device. The Chief Mate correct the painter arrangements on the spot. 74 SOLAS(14)III/13 10c
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 16 December 2017
Resolution: Corrected on the spot to float free arrangment
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 16 December 2017 Resolved
0715-Detection- Maintenance. Test and inspection shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire fighting systems and appliances. PSCO observed the crew testing the on board heat detection system with a self made heat lamp. Crew was unable to provide testing procedures that identified this as an approved fire detection testing method. 74 SOLAS (14) II-2/14/2/2/1 16a
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 21 December 2017
Resolution: PSC NOLA received documentation from BV satisfying the requirement.

Ownership record