SKOMER ISLAND is a 2010 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in July 2026, along with 4 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 13 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it34844 - Convention (Subpart B), Gross Ton 20209 - Convention (Subpart B), Net Ton 61510 - Dead Weight, Ton 72322 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 March 2020Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2020
Resolution: Received, reviewed, and accepted NKK class report stating the educator was replaced with a spare onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 March 2020Resolved
THE MACHINERY BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO IDENTIFIED HOLED INTERCONNECTION BALLAST LINE BETWEEN NO 1 AND NO 2 BALLAST PUMPS. SOLAS 74(14 CONS) II-1/26.1, 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2020
Resolution: Received, reviewed, and accepted NKK class report stating hole was temporaryily repaired with a doubler and will be permanently fixed by May 9, 2020.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 March 2020Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 2 OF THIS REGULATION SHALL COMPLY WITH PARAGRAH 6 OF THIS REGULATION. IN ADDITION, IT SHOULD BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED. THE SYSTEM SHALL ALSO BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVALS, THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. THE OWS IS UNABLE TO RECIRCULATE EFFLUENT OVER 15 PPM BACK TO THE BILGE TANK AS REQUIRED BY MEPC 107(49) DUE TO CLOGGED RECIRCULATION PIPING. MARPOL I/14.7, 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2020
Resolution: Received, reviewed, and accepted NKK class report stating recirculation piping was unclogged and a satisfactory test was observed.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 11 January 2016Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature or other phenomena to which the detector is designed to respond. Cont in narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 February 2017
Resolution: Received reciept and photographic evidence of proper detector testing equipment.