Records from 2011 to 2026. Most recent: inspection, 4 January 2026.
Inspection history · 29
4 January 2026
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8289771
28 December 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8287220
25 December 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8287226
12 November 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7349000
24 November 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6585782
23 August 2018
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6520704
23 August 2018
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6521017
17 May 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6415899
6 March 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6367164
15 February 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6355665
5 February 2018
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6350225
25 January 2018
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6343206
26 December 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6329206
30 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6315264
29 November 2017
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6314590
29 November 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332249
12 June 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6173374
17 May 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148134
16 May 2016
ISPS II Exam · Ballast Water Examination · NPV Safety Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5878291
29 April 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5865465
5 April 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5847424
26 March 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5840963
10 December 2015
Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5778976
10 December 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5779222
25 June 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4899584
5 March 2014
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4810133
3 January 2012
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4214696
1 January 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4216878
29 December 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4215689
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 December 2025
Resolved
Paint lockers shall be protected by a water spraying or sprinkler system.PSCO observed paint being stored in a section of the paint locker not protected by fixed fire protection system (sprinkler)
74SOLAS(20)II-2/10.6.3.1.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 January 2026
Resolution: Flag provided documentation to the movement of paint sotres arranged in the paint locker for the sufficient supression of fixed fire fighting in the space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel's main diesel engine experienced a loss of propulsion.
SOLAS 74 (2020cons) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2021
Resolution: Received flag attestation to repair of #6 cylinder.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 15 February 2018
Resolved
Vessel reported the main engine governor bridge control has malfunctioned.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 6 March 2018
Resolution: Received class report stating vessels governor bridge contral has been repaired and is fully functional
Engineering › Compressed Air System (control) › Valve
Issued 29 November 2017
Resolved
Vessel experienced a loss of control while getting underway. Crew believes the loss of control was due to a solenoid that malfunctioned.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 December 2017
Resolved 7 December 2017
Resolution: Pneumatic valve has been renewed all tests SAT.
Communications › Alarms/Indicators › General Alarm
Issued 12 June 2017
Resolved
0675 74SOLAS(14 Cons)III Reg. 6.4.2 The vessel's fire alarm, abandon ship, and public announcement are not operable.
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 28 June 2017
Resolution: Vessel provided class report attesting to fully operational alarm and PA system.
Accommodation/Occupational Safety › Ventilation › General
Issued 17 May 2017
Resolved
74SOLAS(2014CONS)I/11(a) 9800 - PSCE IDENTIFIED WHEN EMERGENCY GENERATOR WAS STARTED EXHAUST WAS WITNESSED IN SPACE AND PORTABLE MONITORING EQUIPMENT IDENTIFIED 20-22 PPM CARBON MONOXIDE IN SPACE
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: SECTOR DELAWARE BAY RECEIVED A CLASS REPORT TO CLEAR DEFICICENCY. DOCUMENT IS IN DOCUMENT TAB
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 17 May 2017
Resolved
74SOLAS(14CONS)I/11(a) 9800- PSCO IDENTIFIED OIL CONSUMPTION UNDER MAIN ENGINE CRANKSHAFT AND AROUND 3RD GENERATOR GOVENOR.
Action required: 705 - Other - as specified
Resolved 18 May 2017
Resolution: CORRECTED ON THE SPOT
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 16 May 2016
Resolved
1420 - The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persnons on board. PSCO's observed excessive amounts of oil around the main engine, auxiliary engines, and oil purifier room. 74SOLAS(14)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2016
Resolved 18 May 2016
Resolution: CLass report attested to the condition of the engine room. See attached doument for class report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 May 2016
Resolved
The OWS system shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. The 3-way valve on the OWS is not operating properly.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 June 2016
Resolution: Solenoid valve was replaced. See report in documents section.
Engineering › Bilge Water Management System › Pump
Issued 16 May 2016
Resolved
1440 - An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment and for which other efficient means of pumping are provided, under all practical conditions. The oil sludge transfer pump is inoperable. 74SOLAS(04)II-1/21.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2016
Resolved 1 June 2016
Resolution: New sludge pump was installed. See Documents tab for receipt.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 May 2016
Resolved
1230 - Satisfactory means (in the form of guard rails) shall be provided for the protection of the crew in the machinery spaces. The guard rail aft of the main engine on the lowest level of the engine room is severed. ICLL I/25.4
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 May 2016
Resolved 15 June 2016
Resolution: Received and reviewed class survey report given by DNV-GL. No further action. See attached document.
Accommodation/Occupational Safety › Ventilation › General
Issued 16 May 2016
Resolved
0599 - Machinery spaces of category A shall be adequately ventilated to ensure that when machinery is operating at full power in all weather conditions an adequate supply of air is maintained. There is a temporary fix to the ventilation in place to aid the cooling of auxiliary engines. 74SOLAS(04)II-1/35
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Received and reviewed class survey report given by DNV-GL. No further action. See attached document.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 16 May 2016
Resolved
0199 - The frequency of the test and inspection for bunker lines required by this section for vessels must be annually. A bunker line test has not been completed since 15MAY15. 33CFR156.170(f)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 15 June 2016
Resolution: Received and reviewed class survey report given by DNV-GL, and also report from the master attesting to the bunker line test. No further action. See attached document.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 March 2016
Resolved
The condition of the ship and its equiptment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea. During operational test of the Oil Water Separator the second stage filter began to leak as it was pressurized. 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 April 2016
Resolution: Second stage filter pin hole has been repaired by specialist using belzona repair procedures and found satisfactory. CC imposed for permanent repairs to be completed with 2016-07-07.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 10 December 2015
Resolved
Whenever an accident occurs to a ship or defect is discovered, which affects the safety of the ship or efficiency of its equipment, the Master should at the earliest opportunity report to the adminstration who shall cause an investigation to be initiated. Vessel experienced a loss of propulsion while outbound from Wilmington Marine Terminal.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2015
Resolution: Received class report detailing a replacement of a pressure switch on the NO. 7 cylinder