IRENES RAY

IRENES RAY is a freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in February 2024, along with 7 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 15 February 2024.

Built
Not recorded
Last inspected
15 February 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 February 2024
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9322504
1105785
Flag
LIBERIA
Maury page id
psix-1105785

Documentation record

Tonnage as PSIX records it44132 - Dead Weight, Metric Ton
57052 - Displacement, Metric Ton
35573 - Convention (Subpart B), Gross Ton
19496 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

15 February 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7866088
6 May 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5870866
20 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5859469
3 April 2016 MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5846067
31 March 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5844613

Deficiency record · 7

Engineering › Sea-water System (primary cooling) › Piping
Issued 3 April 2016 Resolved
1400: The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected to reduce danger of persons on board. Top bracing 1,3 and 5 on M/E are leaking. Shaft bearing is leaking. Crew is using homemade device to fill generators, see narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2016
Resolution: Received Class Report
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 3 April 2016 Resolved
0715: The function of the fixed fire detection and fire alarm system shall be periodically tested to the satisfaction of the administration. Vessel does not have appropriate means of testing flame detection system, 74 SOLAS (14) II-2/7.3.2, 40ac.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2016
Resolution: Received Class Report
Personnel › Training › Ship's Business
Issued 3 April 2016 Resolved
3091: The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of the relevant rules, regulation , codes and guidelines. C/E does not understand proper recording of entries in ORB. When inspection the engine room, C/E wanted to enter with shorts, tee shirt and shower shoes. When asked about proper PPE, See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 3 April 2016
Resolution: Spoke with the Captain and Chief Engineer.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 March 2016 Resolved
MARPOL ANNEX I REG 14.2 17ac Except as specified in paragraph 3 of this regulation, any ship 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with paragraph 7 of this regulation. The Oily Water Separator was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2016
Resolution: Receieved class report stating the deficiency has been corrected
Deck/Cargo › Ballast › Pumps
Issued 31 March 2016 Resolved
SOLAS74(2014 CONS.) I/11(a) 40ac The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulationsto ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The number 2 ballast water pump is leaking excessively.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2016
Resolution: Received Class Report
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 31 March 2016 Resolved
SOLAS74(2014 CONS.) II-1/45.5.6 Terminations and joints in all conductors shall be made as to retain the original electrical, mechanical, flame-retarding and, where necessary, fire-resisting properties of the cable. The Anti-Fouling System was re-wired outside the junction box and not approved by class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2016
Resolution: Received Class Report
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 31 March 2016 Resolved
SOLAS74(2014 CONS.) II-2/9.3.1. 40ac SEE NARRATIVE FOR SITE INFORMATION Multiple cable trunk rooms had penetrations on class "A" boundaries.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 May 2016
Resolution: Received Class Report

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.