MAURY USCG vessel records
← All vessels

SAFESEA RAMA

SAFESEA RAMA is a freight ship. The Coast Guard has recorded 51 inspections since 2017, most recently in August 2025, along with 24 deficiencies and 23 operational controls.

Records from 2017 to 2025. Most recent: inspection, 11 August 2025.

Built
Not recorded
Last inspected
11 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 August 2025
…with no type recorded18
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9364356
3E7256
1105787
Flag
PANAMA
Maury page id
psix-1105787

Documentation record

Tonnage as PSIX records it9940 - Convention (Subpart B), Gross Ton
5020 - Convention (Subpart B), Net Ton
5020 - Simplified, Net Ton
13630 - Dead Weight, Metric Ton
18978 - Displacement, Metric Ton
9940 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 51

11 August 2025 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8205236
3 April 2025 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8104407
27 March 2025 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8100571
18 March 2025 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8095541
27 February 2025 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8085494
19 February 2025 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8081532
11 February 2025 PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8077109
11 February 2025 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8078073
9 September 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999113
9 September 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999358
6 August 2024 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7974815
6 February 2024 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7859714
3 August 2023 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7746639
11 January 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7618739
18 October 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7579638
24 June 2022 PSC B · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7484702
13 May 2022 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7450245
25 April 2022 Administrative Inspection · PSC B · Ballast Water Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7437432
17 March 2022 Deficiency Check · Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411991
1 March 2022 PSC B · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7422321
23 November 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7356680
16 September 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7312268
4 March 2021 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7149070
16 February 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7141245
19 August 2020 Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7037546
20 February 2020 Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6911320
19 February 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6911321
4 February 2020 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6902281
27 December 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6878875
11 December 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6869757
10 December 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6871314
27 November 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6861788
13 November 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6853639
31 October 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6844348
16 October 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6834075
30 September 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6824774
18 September 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6812929
21 August 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6787843
6 August 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6774779
22 July 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6758182
8 July 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6741423
26 June 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6726410
26 June 2019 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6726537
6 March 2019 Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6636712
24 January 2019 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6613957
1 November 2018 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6571838
9 February 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6352534
12 January 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6336755
21 February 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091611
13 February 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6087423
12 January 2017 PII Safety Exam · Deficiency Check · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6069973

Deficiency record · 24

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 February 2025 Resolved
Machinery spaces of category A above 500 m3 in volume shall, in addition to the fixed fire-extinguishing system required in paragraph 5.1.1, be protected by an approved type of fixed water based or equivalent local application fire -extinguishing system. Vessel's additional fixed water based system is inoperable. 74 solas (20) ch ii-2/10.5.6.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2025
Resolved 27 March 2025
Resolution: RINA surveyor boarded vessel and verified properoperation of water mist system.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 11 February 2025 Resolved
All ships of 300 gross tonnage and upwards shall be fitted with speed and distance measuring device.Vessel's speed measuring device is inoperable. 74 SOLAS (20) CH. V/19.2.3.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2025
Resolved 24 March 2025
Resolution: Flag issued Exemption Cert. with due date 30JUN2026, spped indicator to be repaired at dry dock.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 9 September 2024 Resolved
ANY SHIP OF 400 GROSS TONNAGE AND ABOVE BUT LESS THAN 10000 GROSS TONNAGE SHALL BE FITTED WITH OIL FILTERING EQUIPMENT COMPLYING WITH PARAGRAPH 6 OF THIS REGULATION. PSCO OBSERVED OIL FILTERING EQUIPMENT IS NOT OPERATIONAL. MARPOL ANNEX 1/14.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2024
Resolved 25 September 2024
Resolution: Received class report attesting to repair of oil filtering equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2024 Resolved
During exam, PSCO discovered discoverd #2 and #3 generators were missing lagging on turbo chargers.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 February 2024
Resolved 6 February 2024
Resolution: Prior to departure, chief engineer was able to replace missing lagging to the satisfaction of the Couast Guard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 28 April 2022 Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. Vessel was not complying with SMS procedures concerning ballast water management and record keeping. 74 SOLAS (2020 Cons) IX/3.1 ISM Code 2.2 17abc
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2022
Resolved 13 May 2022
Resolution: PSCO's attended vessel and cleared deficiency.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 28 April 2022 Resolved
Maintain a Ballast Water Management that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. Vessel's BWM plan requires ballast water management records are maintained and up to date, including the ballast water record book . There are no records of any ballast water operations since FEB22. 33CFR151.2050 (g) 17abc
Action required: 17 - Rectify deficiencies prior to departure
Due 11 May 2022
Resolved 13 May 2022
Resolution: PSCOs attended vessel and cleared deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo ship safety equipment (including exemption)
Issued 28 April 2022 Resolved
A certificate called CSSEC shall be issued. PSCO's identified the CSSEC designated 28 immersion suits onboard. The fire control plan identifies 30 immersion suits onboard. 74 SOLAS (2020 Cons) I/12(a)(iii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2022
Resolved 28 April 2022
Resolution: DNV corrected form E to 30 immersion suits
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 March 2022 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least “A-0” class divisions and be protected by self-closing doors at all levels. PSCOs observed multiple self-closing fire doors that wouldn’t close, and one missing self-closing mechanism entirely. 74 SOLAS (04 Cons.) Ch. II-2 / Reg. 9.2.3.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2022
Resolution: vessel submitted a class report from DNV attesting to the completed repairs on the fire doors
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 March 2022 Resolved
The following fire protection systems shall be kept in good order as to ensure their required performance if a fire occurs. … . Fire detection and fire alarms system. PSCOs observed several smoke detectors in machinery spaces were found to be mounted on improper base, and one was found to be damaged with exposed wiring. 74 SOLAS (04 Cons.) Ch. II-2 / Reg. 14.2.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 2 April 2022
Resolution: Deficiency rectified satisfatory
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2022 Resolved
Whenever there is a hazardous condition either on board a vessel or caused by a vessel or its operation, the owner, agent, master, operator, or person in charge must immediately notify the nearest Coast Guard Sector Office… . PSCOs were notified by the captain that there was a fault in the Gyro Compass prior to arrival into Port Everglades. This condition was not relayed to the Coast Guard. 33 CFR 160.216(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2022
Resolved 2 April 2022
Resolution: Deficiency rectified satisfactorily; read in narrative - no action taken.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 March 2022 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place. PSCOs observed many oxygen and acetylene bottles not in a rack, and outside the lockers designed to store these cylinders. 46 CFR 147.60(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2022
Resolved 25 April 2022
Resolution: Vessel provided class report and landing report showing that they removed 45 oxygen and acetylene bottles. Files uploaded into documents.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 16 September 2021 Resolved
The angular position of the rudder shall...be recognizable in the steering gear compartment. Rudder angle indicator in steering gear compartment and engine control room do not accurately reflect rudder position. Rudder angle indicator does not read past 20 degrees port. SOLAS 74 (Cons. 2004) 11-1 29.11.2.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2021
Resolved 23 November 2021
Resolution: Received [name withheld] confirming confirming repairs to the indicator.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 February 2020 Resolved
Where "A" class divisions are penetrated, such penetrations shall be tested in accordance with the fire test procedures code... bulkhead between corridor 221 and spare store and engine office were modified with penetrations to provide passage of cable. 74 SOLAS (14) 11-2 9/3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Received email from vessel on 20FEB20 @ 2025 containing class report from DNV GL surveyor; penetrations were replaced by welded pipes and suitably plugged with fire proof material.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 February 2020 Resolved
The fire system of doors shall be equivalent to that of the divisions in which they are fitted... door on 221 corridor had quarter inch penetration. 74 SOLAS (14) 11-2 9.4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2020
Resolved 20 February 2020
Resolution: Received email from vessel on 20FEB20 @ 2025 containing class report from DNV GL surveyor; penetration in door was sealed and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 February 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Ship had built an unauthorized space for storage under stairwell in main deck made of wood. 74SOLAS(14 Cons) 1/11a 16c, 10c
Action required: 10 - Deficiency Rectified
Due 5 March 2020
Resolved 20 February 2020
Resolution: Ship's crew removed the unauthorized storage space by removing the wood bulkheads and supports. Space to original condition.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 March 2019 Resolved
07124 - Maintenance of Fire Protection Systems - Maintenance testing and inspections shall be carried out based on te guidelines developed by the Organization...ensuring the reliability of the fire-fighting systems and appliances. PSCOs observed annual servicing certificates for the water mist and cargo hold smoke detections systems were expired. The Master provided documentation of request for servicing submitted to the company on 24OCT18. Additionally, the smoke detector located above the main engines was not operable. - 74 SOLAS 2004 con. II-2/14.2.2.1 - Action taken 17bc.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2019
Resolved 7 March 2019
Resolution: Received and reviewed class report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 March 2019 Resolved
13108 - Operation of Machinery - Ships shall be designed, constructed, and maintained in compliance with structural, mechanical, and electrical requirements of a class society. The exhaust system for the main engine is leaking into the engine room through the exhaust piping. - 74 SOLAS 2004 con. II-1/3-1 - Action taken 17bc.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2019
Resolved 7 March 2019
Resolution: Received and reviewed class report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 March 2019 Resolved
03110 - Manholes/Flush Scuttles - Closing appliances which are kept permanently closed at sea to ensure watertight integrity of internal openings shall be provided with notice...that it is to be kept closed at sea. The starboard side void is open and is being used as a storage space with the watertight manhole cover removed. - 74 SOLAS 2004 con. II-1/25-9.5 - Action take 17bc.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 6 March 2019
Resolved 7 March 2019
Resolution: Received and reviewed class report.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 March 2019 Resolved
10119 - Rudder Angle Indicator - The position of the rudder shall be recognizable in the steering gear compartment. The rudder angle indicator repeater visible form the steering gear control system inside the steering gear compartment is malfunctioning. - 74 SOLAS 2004 con. II-2/11.2 - Action taken 16bc.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 7 March 2019
Resolution: Received and reviewed class report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 6 March 2019 Resolved
07105 - Fire Doors/Openings in Fire-Resisting Divisions - Doors required to be self-closing shall not be fitted with hold back hooks. PSCOs observed doors to the steering gear room, auxiliary engine room, and engine room workshop open and fitted with holdback hooks. - 74 SOLAS 2009 con. II-2/9.4.2.2 - Action taken 10c.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 March 2019
Resolved 6 March 2019
Resolution: PSCOs witnessed the crew remove hold back hooks from fire doors in question.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 January 2018 Resolved
Fire doors in galley boundaries shall be self closing and be capable of closing with an angle inclcination of up to 3.5 degrees opposing closure. Galley door is unable to self-close. 74 SOLAS (14 Cons.) II-2/9.4.1.1.5.1. Action taken 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 February 2018
Resolution: Class survey report submitted attesting to correction of deficiency by removal of ventilation nozzle and repair of hinge mechanism.
Engineering › Fuel Oil Service System › Piping
Issued 13 January 2017 Resolved
Excessive fuel leaks were idnetified on the main engine, generator space, and under fuel oil purifiers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 January 2017
Resolution: received class attestation to the correction of this deficiency, see attached class report.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 13 January 2017 Resolved
An unapproved modification was discovered on the fuel line from the emergency generator; a valve had been welded into the line and a rubber hose installed to the main generators.
Condition: Improper Installation
Due 27 January 2017
Resolved 13 February 2017
Resolution: The flexible hose was removed from the installation.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 13 January 2017 Resolved
Crew could not provide proper equipment to test the flame detectors and were testing by lighting a piece of paper on fire and holding it up to the detectors.
Condition: Invalid
Due 27 January 2017
Resolved 13 February 2017
Resolution: Proper test equipment was procrued and placed onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.