Records from 2017 to 2022. Most recent: inspection, 6 July 2022.
Inspection history · 7
6 July 2022
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7498428
12 May 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7449101
12 May 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7451843
29 March 2022
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7418661
26 February 2018
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6361446
9 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6321449
7 December 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6319987
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 July 2022
Resolved
The following vessels must have on board a properly installed, operational Coast Guard approved AIS Class A device. (i) A self-propelled vessel of 65 feet or more in length, engaged in commercial service.
PSCDO received a notification that the vessel's AIS became in operational prior to entering port.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 July 2022
Resolved 6 July 2022
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 6 July 2022
Resolved
Each vessel of 10,000 gross tons or more must have, in addition to the radar under 33 CFR 164.35(a), a second marine radar system that operates independently of the first.
PSCDO received a notification that the vessel's secondary marine radar became in operational prior to entering port.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 July 2022
Resolved 6 July 2022
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 29 March 2022
Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. Port State Control Officer observed fuel oil leaking from jacketed piping system between fuel pump and injector on number 6 cylinder resulting in accumulation of fuel oil. Deficiency corrected on spot by replacing the fuel line. 74SOLAS(04)II-2/4.2.2.5.2
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 March 2022
Resolved 29 March 2022
Resolution: Deficiency corrected on spot by replacing the fuel line.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 March 2022
Resolved
No person may use any equipment listed in paragraph (c) of this section for transfer operations unless the vessel operator, as appropriate, tests and inspects the equipment in accordance with paragraph (c) of this section and the equipment is in the condition specified in paragraph (c) of this section. Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. Port State Control Officer observed bunker lines have not been hydrostatically tested since 2019.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 12 May 2022
Resolution: Received report attesting to testing being done.
Engineering › Fuel Oil Service System › Filter
Issued 7 December 2017
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. Excessive fuel oil leak found in the purifier space. 74 SOLAS (14) II-2/4.1.1
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 9 December 2017
Resolution: Recieved class report attesting to repair and maintenance. See attached.