DOLE INCA is a 2006 freight ship. The Coast Guard has recorded 31 inspections since 2018, most recently in May 2026, along with 14 deficiencies and 12 operational controls, 2 with no removal date recorded.
Records from 2018 to 2026. Most recent: inspection, 31 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it32984 - Convention (Subpart B), Gross Ton 50186 - Displacement, Ton 13452 - Convention (Subpart B), Net Ton 35556 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
31 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 12 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 31
31 May 2026PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8384492
30 November 2025PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8275167
18 May 2025PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8138344
11 February 2025Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8077938
5 February 2025Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8074974
10 November 2024PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8032790
28 October 2024In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8025541
9 June 2024PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7930955
18 January 2024Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7851092
4 January 2024Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7845173
23 May 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695066
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 October 2024Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea with out danger to the shop pr persons on board. During pre departure checks, vessel encountered monitor and control system failure on FPD4 cabinet resulting in the inability for ship to gain propulsion.
74 SOLAS (20) I/11
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 28 October 2024
Resolved 28 October 2024
Resolution: Rcvd Class statement of fact, uploaded to deficiency documents.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 4 January 2024Resolved
All ships of 3,000 gross tons and upwards shall, in addition to meeting the requirements of paragraph 2.5, have: A 3 GHz radar or, where considered appropriate by the administration, a second 9 GHz radar. PSCO was advised by the Vessel's agent that the S-Band Radar remains inoperable after attempted repairs.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2024
Resolution: Received technician report attesting to repairs and flag dispensation closure letter.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 16 June 2021Resolved
Oil filtering equipment referred in this regulation shall be of design approved by the administration and shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. The seal on the control cabinet was broken after last calibration. MARPOL 73/78 Annex I Reg 14.6
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 5 November 2021
Resolution: Class report
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 16 June 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to crew. PSCO witnessed steam leak above cascade tank. SOLAS74(2014) Ch 1, Reg 11(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2021
Resolved 5 November 2021
Resolution: class report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 August 2019Resolved
The condition of the ship and its equipment shall be maintained to conform with the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed excessive quantities of oil in multiple locations in the engine room which pose a significant risk of fire. 1) Oil leaks from #1, #3, & #4 generators. Multiple oil soaked rags and buckets containing 1-2 gallons oil each under generators. Deck underneath generators covered in oil. 2) Significant oil leaks on and under generator fuel oil purifiers. Thick sludge of oil on deck and along purifier space aft bulkhead. 3) Oil soaked lagging on steam pipes & bulkheads, oil covering deck and electrical equipment in space directly below purifier space. 4) Significant accumulation of oil, approx. 25 ft x 25 ft in size, in bilge aft of the main engine. 74 SOLAS (14) I/11
Action required: 30 - Ship detained
Due 26 August 2019
Resolved 16 September 2019
Resolution: Condition of class placed on the vessel to replace oil soaked lagging. See class report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 August 2019Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. 1) Vessel’s safety management system required monthly testing of OWS. Company directed vessel via email in May 2019 to stop using OWS. Vessel has not conducted monthly testing since company email in contradiction of vessel’s SMS manual. 2) Vessel’s SMS required cleaning and identification of leaks per vessel’s SMS form MSOPR-11.15. Excessive oil in engine room indicates that SMS implementation is ineffective. Recommend audit within 30 days. 74 SOLAS (14) IX/3.1 ISM Code A/10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 16 September 2019
Resolution: Received class report
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 August 2019Resolved
Stairways and lift towers which penetrate more than a single deck shall be surrounded by at least “A-0” class divisions and be protected by self-closing doors at all levels. PSCO observed 03 fire doors on main stairwell decks A, F, & G which did not fully self-close. 74 SOLAS (04) II-2/9.2
Action required: 10 - Deficiency Rectified
Resolved 26 August 2019
Resolution: Corrected to the satisfaction of the attending PSCOs
An endorsement shall expire as soon as the certificate endorsed expires or is withdrawn… Third engineer’s flag state endorsement is valid for one month past the national certificate expiration date. Certificate and endorsement are currently valid. STCW I/2.8.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2019
Resolved 16 September 2019
Resolution: Recieved class report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2019Resolved
The Condition of the Ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fot to proceed to sea without danger to the ship or the persons onboard. Vessel reported loss of propultion while on outbound transit in the Delaware River on 15 July 2019
Action required: 10 - Deficiency Rectified
Due 16 July 2019
Resolved 16 July 2019
Resolution: Class report details main cause and correction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 April 2019Resolved
The vessel is to prevent the ignition of combustible material and flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed an excessive amount of oil in the bilge pocket around the flywheel. Ship crew indicated the oil was caused by the MDE scrapper ring to seal the crankcase. Due to the location oil can only be cleaned when the MDE is stopped. The MDE must be repaired to prevent excessive amounts of oil from leaking and accumulating around the flywheel when underway.
74 SOLAS (14) II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 16 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 April 2019Resolved
PSCO observed ship crew cleaning oil around #2 and #4 aux gen where excessive oil was found. The oil was cleaned prior to PSCO departure. PSCO asked crew if the gens were due for overhaul and the crew indicated the request for parts and support was sent to the company in Jan. Both generators must be repaired to prevent excessive oil.
74 SOLAS (14) II-2/4.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2019
Resolved 16 September 2019
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2018Resolved
1510 - NAVIGATION EQUIPMENT - SHIPS, IRRESPECTIVE OF SIZE, SHALL HAVE:... AN ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM (ECDIS) IS ALSO ACCEPTED AS MEETING THE CHART CARRIAGE REQUIRMENTS... THE MONITOR ON THE VESSEL'S ECDIS IS NOT OPERATIONAL.
DEFICIENCY SHALL BE RECTIFIED BY 14JUN2018 AS STATED ON THE DISPENSATION LETTER (REF: 17361-202390) FROM LIBERIA. - 74 SOLAS (14) 19.2.1.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 14 June 2018
Resolution: Email notification was sent with photographs of the properly installed radar screen. Verified by DNV-GL via email.
Navigation › Piloting/Steering › Swing Meter
Issued 4 April 2018Resolved
1581 - Rudder angle indicator - All Ships 500 GT and upwards shall... have rudder,... indicators... to determine and display rudder angle... readable from the conning position. The rudder angle indicator on the starboard bridge wing does not function properly. - 74 SOLAS (14) V/19.2.5.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 7 June 2018
Resolution: Vessel submitted a class report attesting to the repairs and functionality of the bridge wing rudder angle indicator.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 April 2018Resolved
1499 - Other machinery (prop or aux) - Emergency generating sets shall be capable of being readily started. The emergency generator was unable ot be started from the battery set. - 74 SOLAS (04) II-1/44.1
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Crew worked on the batteries and was eventually able to start the e-gen.