MAURY USCG vessel records
← All vessels

ZIM BALTIMORE

ZIM BALTIMORE is a 2010 freight ship. The Coast Guard has recorded 12 inspections since 2019, most recently in August 2026, along with 7 deficiencies and 4 operational controls.

Records from 2019 to 2026. Most recent: operational control imposed, 9 August 2026.

Built
2010
Last inspected
9 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 August 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2019–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9395953
1105855
Flag
LIBERIA
Maury page id
psix-1105855

Documentation record

Tonnage as PSIX records it40741 - Regulatory (Subpart C or D), Gross Ton
24178 - Regulatory (Subpart C or D), Net Ton
40741 - Convention (Subpart B), Gross Ton
52360 - Dead Weight, Ton
68242 - Displacement, Ton
24178 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

9 August 2026 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8458664
28 January 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8302768
12 November 2025 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8267197
5 September 2025 PSC B · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8226872
18 February 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8080579
17 December 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8048409
12 December 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7608132
14 March 2022 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7411570
14 March 2022 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7411718
13 April 2021 PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 7167830
10 July 2020 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7002708
28 June 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6728597

Deficiency record · 7

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 September 2025 Resolved
The company and the ship shall comply with the requirements of the international Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. The nature of the below deficiencies provides objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, must be submitted prior to clearance of this deficiency and departure. 74SOLAS(24) IX/3.1 ISM Code Part A/10.1 Code 30abc
Condition: Invalid
Action required: 30 - Ship detained
Resolved 6 September 2025
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 September 2025 Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for sue. PSCOs observed that the pneumatic tube was disconnected from CO2 bottle E1 D9913. According to the fixed CO2 system diagram the engine room requires 215 CO2 bottles. The disconnected pneumatic tube would have rendered 14 bottles incapable of pneumatic release, leaving only 210 bottles available for pneumatic release to the engine room. According to the ship's maintenance records the fixed cCO2 system was subject to an annual inspection on 17FEB2025 and monthly checks by the crew on 07 occasions since the last annual inspection. The last monthly check was conducted on 19AGU2025 and stated that all discharge piping and pneumatic tubing was not damaged. however, the crew member responsible for conducting the monthly checks of the fixed CO2 system stated that he does not inspect the pneumatic tubing during the monthly checks. 74SOLAS(24) II-2/14.1.1 Code 30abc
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 September 2025 Resolved
The machinery, boilers, and other pressure vessels, associated with piping systems and fittings shall be of design and construction adequate for the service for which they are intended...PSCOs observed that the jacket water pressure gauge on DG#2 and the fuel oil pressure gauge on DG#3 were not functioning properly. 74SOLAS(24) II-1/26.1 Code 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 June 2019 Resolved
CODE: 13199 CITE: 74 SOLAS (14) I/II(b) ACTION: 60ac AFTER ANY SURVEY HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGMENTS, MACHINERY, EQUIPMENT, AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. THE #2 SHIP'S SERVICE AIR COMPRESSOR IS MISSING.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 June 2019
Resolved 1 July 2019
Resolution: Recieved satisfactory class report from DNV-GL attesting to the need for only 02 start air compressors.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 June 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2019
Resolved 10 July 2020
Resolution: Reviewed attestation that audit was conducted to remediate the lack of notification to Flag and Class.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 June 2019 Resolved
CODE: 11135 CITE: 74 SOLAS (14) III/20.2 ACTION: 40ac BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES THROUGHOUT THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. THE FWD HATCH OF THE STBD SIDE RESCUE BOAT HAS A CRACK IN THE LIP CONNECTING TO THE SEAL THAT AFFECTS THE WATERTIGHT INTEGRITY.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2019
Resolved 10 July 2020
Resolution: Recieved class and tech report with photos showing proper repair of the lifeboat's forward hatch.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 June 2019 Resolved
CODE: 07113 CITE: 74 SOLAS (14) I/II(a) ACTION: 40ac THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ABOARD. THERE IS A SPOOL PIECE BEING USED AS A PERMANENT REPAIR BETWEEN THE # 1 FIRE PUMP STRAINER AND THE PUMP SUCTION.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 June 2019
Resolved 10 July 2020
Resolution: Received class report with photos showing permenant repairs made to piping on the suction side of the #1 fire pump.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.