← All vessels
SILVER QUEEN
Freight Ship · Ro-Ro Cargo Ship class · Built 2000s · USCG Southwest District (CGD-SW) · Other hulls named SILVER QUEEN
SILVER QUEEN is a 2009 freight ship. The Coast Guard has recorded 22 inspections since 2011, most recently in November 2024, along with 5 deficiencies and 6 operational controls, 1 with no removal date recorded.
Records from 2011 to 2024. Most recent: inspection, 18 November 2024.
- Built
- 2009
- Last inspected
- 18 November 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
9427938 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3E3429
1105862
Flag
PANAMA
—
Maury page id
psix-1105862
Inspections, by type
…with no type recorded10
Years with a record
8 calendar years (2011–2024)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it47020 - Convention (Subpart B), Gross Ton
14106 - Convention (Subpart B), Net Ton
26032 - Displacement, Metric Ton
11372 - Dead Weight, Metric Ton
14106 - Convention (Subpart B), Net Ton
26032 - Displacement, Metric Ton
11372 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
18 November 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8036384
11 May 2023
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681705
5 August 2022
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7525334
5 August 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7525682
4 August 2022
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7524699
1 August 2022
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7521970
30 July 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7522834
29 July 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7517009
29 July 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7519452
29 July 2022
COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7519458
28 July 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7518974
26 December 2019
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6876895
5 May 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6679851
12 December 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6594219
15 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6558485
13 January 2018
ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6335586
27 November 2017
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6315753
29 September 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6277498
4 April 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6119086
27 September 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6010314
26 September 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6010208
16 December 2011
ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4209328
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 November 2024
Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. No. 02 refrigerator units radiator coil fins were found corroded in low pressure CO2 room. (74SOLAS(20) II-2/14.2.1.2)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service in which they are intended. Excessive jacket water leaks exist on the on main diesel engine cylinder heads 01,03, and 05. 74SOLAS(04)II-1/26.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 November 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials and flammable liquids. Diesel fuel oil valve in engine room leading from No. 7 tank is leaking fuel into bilge. 74SOLAS(20) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 November 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Low pressure CO2 sight gauge lower valve is corroded, frozen and seized. 74SOLAS(20) II-2/14.2.1.2
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 April 2017
Resolved
Vessels S-Band radar is non operational.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.