← All vessels
CAPTAIN A. STELLATOS
CAPTAIN A. STELLATOS is a tank ship. The Coast Guard has recorded 3 inspections in 2025, along with 2 deficiencies.
Records in 2025. Most recent: inspection, 19 September 2025.
- Built
- Not recorded
- Last inspected
- 19 September 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Inspection record
Last inspected
19 September 2025
Deficiencies
2 recorded · 0
without a recorded resolution
Operational controls
None recorded without a removal date
Years with a record
1 calendar year (2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
9439670
V7A2235
1106015
Flag
MARSHALL ISLANDS
Maury page id
psix-1106015
Documentation record
Tonnage as PSIX records it57144 - Convention (Subpart B), Gross Ton
32440 - Convention (Subpart B), Net Ton
105849 - Dead Weight, Ton
122943 - Displacement, Ton
32440 - Convention (Subpart B), Net Ton
105849 - Dead Weight, Ton
122943 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 3
19 September 2025
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8237411
18 September 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8236910
15 September 2025
COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8227707
Deficiency record · 2
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2025
Resolved
"In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the Organization". PSCO witnessed 37 cracked explosion proof lights in the cargo pump room and storage lockers on deck.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 September 2025
Resolved
"Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter, or heater from coming into contact with heated surfaces". PSCO observed fuel oil soaked lagging on two of three generators, fuel oil dripping from filter housing. Also found lube oil soaked lagging on return line on main diesel engine.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.