MAURY USCG vessel records
← All vessels

MAURITIUS PRIDE II

MAURITIUS PRIDE II is a 2007 freight ship. The Coast Guard has recorded 12 inspections since 2016, most recently in January 2025, along with 7 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 27 January 2025.

Built
2007
Last inspected
27 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9359935
1106039
Flag
CYPRUS
Maury page id
psix-1106039

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it12583 - Dead Weight, Metric Ton
18270 - Displacement, Metric Ton
9938 - Convention (Subpart B), Gross Ton
4265 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 12

27 January 2025 Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8067558
23 January 2025 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8068969
22 January 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8067531
31 July 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7971164
29 July 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7970014
22 July 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7964537
7 April 2021 PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7169373
15 August 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7033453
11 August 2020 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7029057
16 April 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6663406
2 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6383246
8 November 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6036106

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 31 July 2024 Resolved
External High-Pressure fuel delivery lines between the high pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure line failure. PSCO observed deteriorating lagging on the mast and second high-pressure fuel delivery lines Cite 74 SOLAS (09') II-2/4.2.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2024
Resolved 27 January 2025
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excess oil accumulating under the auxiliary generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 August 2024
Resolved 31 July 2024
Resolution: Rectified before depature
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 31 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed missing guard railing forward of the port engine level on the upper room deck.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 August 2024
Resolved 31 July 2024
Resolution: Rectified before depature
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 April 2021 Resolved
04114- Emergency source of power - Emergency generator- The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted oil around fuel injector ports and valve covers on the emergency generator. Additionally, when the crew started the emergency generator, it produced smoke in the emergency generator space. 74 SOLAS (14) I/11(a) 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 27 January 2025
09 - Working and Living Conditions › 092 - Working Conditions › Entry dangerous spaces
Issued 7 April 2021 Resolved
09221 - Entry dangerous spaces - Provisions concerning the prevention of occupational accidents shall be laid down by laws or regulations, codes of practice or other appropriate means. In particular, thes provisions shall cover special safety measures on or below deck. At approximately 11:00 EST PSCO noted the void space on the starboard side forward bulkhead of the engine room was open beyond permitted time 0800-0900. PWSA, 46 USC 70002, ILO 147 Accident Prevention/Basic Requirements/3 (d) 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 7 April 2021
Resolved 7 April 2021
Resolution: The hatch cover was properly installed on the void manhole.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 April 2021 Resolved
13103 - Gauges, thermometers, etc - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed the tank level gauge on the boiler condensate tank leaking from the upper connection point. 74 SOLAS (14) I/11(a) 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2021
Resolved 27 January 2025
Engineering › Freshwater System (air cooling) › Hose
Issued 8 November 2016 Resolved
The conditions of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Inspector identified broken sea water cooling pipe for freezer unit and a temporary flexible hose was installed in place instead of fixed piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 November 2016
Resolution: Received class report report of survey to the satisfactory attestation of repairs to the reefer saltwater cooling system. Vessel is cleared to depart.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.