This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it12137 - Convention (Subpart B), Gross Ton 5493 - Convention (Subpart B), Net Ton 22906 - Displacement, Metric Ton 16744 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 10
31 August 2019Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6799589
1830-Cargo Transfer- Annually or as part of the biennial inspections, each transfer pipe system must not leak under static liquid pressure at least 1.5 times MAWP. Vessel MAWP is 12.5, Last test meeting the 1.5 requirement was conducted 25sep12. Vessel is restricted to a discharge pressure of 8 BAR, hydrostatic testing must be completed prior to next US port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2017
Resolved 30 September 2017
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 28 June 2016Resolved
1899-Other (tankers)- Where the atmosphere in double hull spaces cannot be reliably measured using flex gas sampling hoses. Such spaces shall be fitted with permanent gas sampling lines. Vessel SMS requires the crew to conduct sampling every 3 hrs if fixed gas system is inoperable. Crew has only been checking atmosphere 1 time per day. 74SOLASII-2/5.7.2.2
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 28 June 2016
Resolution: Vessels master was instructed and reminded of SMS policy onboard and master instructed [name withheld] to conduct check every 3 hrs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.