MAURY USCG vessel records
← All vessels

GEORGIOS P

GEORGIOS P is a 2010 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in April 2026, along with 2 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 10 April 2026.

Built
2010
Last inspected
10 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9476680
1106272
Flag
GREECE
Maury page id
psix-1106272

Documentation record

Tonnage as PSIX records it33044 - Convention (Subpart B), Gross Ton
19231 - Convention (Subpart B), Net Ton
67681 - Displacement, Metric Ton
57051 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

10 April 2026 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8330988
24 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8331004
17 December 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610362
1 October 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7569770
29 July 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7519581
30 April 2021 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7181832
15 July 2016 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5945703

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 April 2021 Resolved
07126-Oil accumulation-Means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaking from main diesel engine at NBR 1, NBR 3, NBR 5, and NBR 6 cylinders. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2021
Resolution: Bolts to fuel injectors and high pressure fuel lines have been tightened.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 30 April 2021 Resolved
08103-Fire alarm-The function of the fixed fire detection and fire alarm system shall be periodically tested. PSCO observed ship did not have proper testing equipment to testing equipment to test flame detector. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2021
Resolution: New flame detector equipment purchased and tested in presence [name withheld] sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.