MAURY USCG vessel records Sign in
← All vessels

SS JERSEY GIRL

SS JERSEY GIRL is a 2011 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2011, most recently in May 2026, along with 38 deficiencies and 1 operational control.

Records from 2011 to 2026. Most recent: inspection, 26 May 2026.

Built
2011
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1106476
Flag
UNITED STATES
—
Maury page id
psix-1106476

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (2011–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.6 ft × 13.5 ft × 2.7 ft
Registered tonnagegross 10 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderERCOA INDUSTRIES · BRAHAM, MN, UNITED STATES · built 2011
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationTri Hull
Hailing portHEWITT, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

26 May 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8380468
14 April 2026 Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8349579
28 May 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8146624
20 March 2024 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7882578
20 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7827830
12 May 2022 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7448921
18 August 2021 Deficiency Check · COI Inspection · Initial Certification · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7282403
18 July 2021 Type not recorded
No type recorded · Station Kings Point · USCG Northeast District (CGD-NE) · Activity 7275204
18 June 2021 Deadweight Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7229269
12 April 2021 Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7173325
2 June 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6953155
16 April 2020 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6940128
6 December 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6868984
28 June 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6451283
2 April 2018 Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6393345
1 March 2017 Administrative Inspection · Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6096796
11 April 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5851604
10 May 2012 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4307030
16 February 2011 Construction Oversight · Deadweight Survey · Initial Certification
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3973934

Deficiency record · 38

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 May 2025 Resolved
A vessel on a Lakes, Bays, and Sounds or Rivers route must carry: three red hand flare signals. Found expired red hand flares. Provide new. 46 CFR 180.68(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2025
Resolution: Received photo with unexpired red flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2024 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Vessels current charging arrangement does not include an ammeter. 46 CFR 183.350(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 April 2024
Resolution: Vessel installed and ammeter.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI noticed multiple dead end wires located under console. Remove or properly secure dead end wires and mount fuse panel. 46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 April 2024
Resolution: Vessel removed dead end wires.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 20 March 2024 Resolved
The alcohol testing devices need not be carried on board each vessel if obtaining the devices and conducting the required alcohol tests can be accomplished within 2 hours from the time of occurrence of the SMI. Vessel does not have test needed to conduct alcohol testing. 46 CFR 4.06-15(a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 April 2024
Resolution: Vessel purchased alcohol swabs.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 20 March 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's COI. 46 CFR 16.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 April 2024
Resolution: Vessel provided consortium information for employess.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 November 2023 Resolved
To maintain a valid certificate of inspection, you must complete your annual inspection within the periods specified in 46 CFR 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel owner/operator failed to renew Certificate of Inspection in the required time period outlined in the regulations.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2024
Resolution: Vessel completed COI renewal inspection.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 August 2021 Resolved
The vessel's new seating arrangement and bar area has blocked aft drainage outlets. Owner will install risers/spacers under bar and railings to provide adequate drainage. Due to vessel operating on a small inland lake, operator is allowed to continue operations and resolve drainage prior to 2022 operational season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 13 May 2022
Resolution: Operator installed risers under bar to allow for 1" vertical clearance and access to drainage ports.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 18 August 2021 Resolved
Vessel currently does not have draft marks. DWS conducted, awaiting decision on location of marks.
Action required: 705 - Other - as specified
Resolved 13 May 2022
Resolution: Verified installation of draft marks welded to the hull.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 August 2021 Resolved
During the man overboard drill the ladder utilized for access to the water was not secured to the deck and produced an additional hazard for the crew member.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 November 2021
Resolution: Vessel installed ladder.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 April 2021 Resolved
Conduct satisfactory stability test in accordance with Marine Safety Center guidelines prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 April 2021 Resolved
Complete a satisfactory Certificate of Inspection exam prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 January 2022
Resolution: Vessel was issued a temporary COI during its COI inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 December 2019 Resolved
Each certificated vessel must undergo an annual inspection within three months before or after each anniversary date. SS JERSEY GIRL's certification date is 13APR2016, and thus was required an Annual Inspection no later than 13JUL2019. Vessel may not carry passengers until an Annual Inspection is completed to the satisfaction of the attending Marine Inspector. - 46 CFR 176.500 (b) (1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2019
Resolved 3 November 2021
Resolution: Vessel is now operating Sec NY. Refer to activitiy 7282403 for NTZ COI.
Lifesaving › Hand Flares › Expired
Issued 1 March 2017 Resolved
RT01: Vessel does not have sufficient number of flares. Provide 3 red and 3 orange distress signals approved in accordance with 46 CFR 160.021. CITE: 46 CFR 180.68(b) Prior to carrying Passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 13 April 2017
Resolution: Sent in pictures and cleared via email
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 March 2017 Resolved
RT02: Vessel needs life ring with 60f life line. Life line provided is only 50ft. CITE: 46 CFR 180.70(c)(2) Prior to Carrying Passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 13 April 2017
Resolution: Sent in pictures and cleared via Email.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 April 2011 Resolved
Conduct new to zone COI inspection IAW 46CFR 176.400
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2011
Resolution: Completed.
Documentation › Certificates/Documents › Stability Letter
Issued 29 April 2011 Resolved
Provide and post valid stability letter for vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2011
Resolution: Completed.
Documentation › Markings/Placards › Capacity Marking
Issued 29 April 2011 Resolved
Post small passenger vessel decal IAW 46CFR 176.310
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Completed.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 April 2011 Resolved
Provide proof of enrollment in an approved chemical testing program. IAW 46CFR16
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 29 April 2011 Resolved
Provide proof of pre-employment drug screening for master and crew. IAW 46CFR16
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete, owner provided proper documentation.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 April 2011 Resolved
Provide training log book to document required crew training, IAW 46CFR185.420
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Reviewed training log, all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 29 April 2011 Resolved
Conduct emergency drills to the satisfaction of the attending marine inspector, IAW 46CFR185.524
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2011
Resolution: Complete.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 April 2011 Resolved
Provide valid certificate of documentation, IAW 46CFR67.7
Action required: 705 - Other - as specified
Resolved 26 May 2011
Resolution: Owner provided proof of COD.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 29 April 2011 Resolved
Provide suitable means for passenger count, IAW 46CFR185.504
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Completed.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 29 April 2011 Resolved
Demonstrate safety orientation for voyage, IAW 46CFR 185.506
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Complete.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 29 April 2011 Resolved
Provide nautical publications for intended route, IAW 46CFR 184.420
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Lifesaving › Hand Flares › Not on Board
Issued 29 April 2011 Resolved
Provide distress signals with suitable storage for intended route, IAW 46CFR 180.68/46CFR 185.614
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 April 2011 Resolved
Provide emergency instructions IAW 46CFR 185.510
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 29 April 2011 Resolved
Affix vessels name and hailing port IAW 46CFR 67.123
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 April 2011 Resolved
Provide first aid kit, IAW 46CFR176.818
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified medical kit onboard and everything is current.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 April 2011 Resolved
Provide portable lights IAW 46CFR 183.430
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified minimum of 02 portable lights onboard.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 29 April 2011 Resolved
Provide suitable ground tackle for vessel, IAW 46CFR 184.300
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 April 2011 Resolved
Provide 43 adult Type-I PFD's for total number of persons on board, IAW 46CFR 180.71
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified 43 adult life preservers in good conditioon onboard and stowed properly.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 April 2011 Resolved
Provide 04 Type-I child size PFD's IAW 46CFR 180.71
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified that owner minimum amount. Owner had 25 child life jackets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 April 2011 Resolved
Provide life jacket donning placards IAW 46CFR 185.516
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 April 2011 Resolved
Provide life ring with attached water light IAW 46CFR 180.70
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified complete, with proper installation.
Fire Fighting › Fire Bucket › Quantity
Issued 29 April 2011 Resolved
Provide fire buckets IAW 46CFR 181.610
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Observed 03 fire buckets with lanyards attached.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 April 2011 Resolved
Provide hand bilge pump IAW 46CFR 182.520
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified manual bilge pump works and is of sufficient capacity.
Engineering › Gasoline Engine (propulsion) › Pump, Cooling Water (4 cycle)
Issued 29 April 2011 Resolved
Demonstrate operational test of vessels propulsion equipment while underway. IAW 46CFR182.200
Action required: 705 - Other - as specified
Resolved 20 May 2011
Resolution: Verified while underway and during man overboard drill.

Ownership record