MAURY USCG vessel records Sign in
← All vessels

W PEARL

W PEARL is a 2010 freight ship. The Coast Guard has recorded 10 inspections since 2012, most recently in August 2023, along with 6 deficiencies and 2 operational controls.

Records from 2012 to 2023. Most recent: operational control imposed, 6 August 2023.

Built
2010
Last inspected
6 August 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9426063 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1106504
Flag
LIBERIA
—
Maury page id
psix-1106504

Inspections, by type

…with no type recorded4
Years with a record 4 calendar years (2012–2023)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it51255 - Convention (Subpart B), Gross Ton
31192 - Convention (Subpart B), Net Ton
108706 - Displacement, Metric Ton
93259 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

6 August 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7761017
3 August 2023 In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7757675
31 July 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7757002
27 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7754082
24 October 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7574181
9 April 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6381181
26 January 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232688
25 January 2012 NPV Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4231749
25 January 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232514
20 January 2012 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4227760

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2022 Resolved
ALL ELECTRICAL APPARATUS SHALL BE SO CONSTRUCTED AND SO INSTALLED AS NOT TO CAUSE INJURY WHEN HANDLED OR TOUCHED IN THE NORMAL MANNER, PSCO OBSERVED TWO HEATING ELEMENTS LOCATED IN STEERING GEAR ROOM REMOVED WITH POWER SUPPLY WIRING REMAINING AND COVERED IN ELECTRICAL TAPE. SOLAS AM II-I/45 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 November 2022
Resolved 3 August 2023
Resolution: Two heating elements (electric heater) which have been removed from position were repaired and placed back to their position in steering gear room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2022 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED. PSCO OBSERVED TLI FOR AFT TANK REMOVED FROM SERVICE. CREW WAS CONDUCTING MANUAL SOUNDINGS. SOLAS 74 AM II-I/26 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 14 November 2022
Resolved 3 August 2023
Resolution: Necessary spare part for the permanent repair have been provided onboard and installed in their position. The APT level indication system was examined and found in order
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 9 April 2018 Resolved
Main and emergency switchboards shall be so arranged as to have an earthed distribution system capable of continuous monitoring. PSCO observed an indication of a dead ground on the 220 volt panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2018
Resolved 13 April 2018
Resolution: Received report from RINA clearing this deficiency. Report stated that the cause was an navigation light on the fore mast causing the ground. Nav light replaced and dead ground resolved.
Engineering › Lubricating Oil Service System › Tube
Issued 9 April 2018 Resolved
The means acceptable to the Administration shall be maintained in proper condition to ensure continued accurate functioning in service. Crew had attached a fabricated gauging device on a self closing safety valve on the stem tube gravity tank flat glass oil gauge that prevented the valve from closing as designed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2018
Resolved 9 April 2018
Resolution: Corrected on the spot.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2012 Resolved
The 15 ppm oil content meter (OCM) should record the date time and alarm status of the 15ppm separator. The recording device should also store data for at least 18 months and display or print a record for inspection. The vessels crew was unable to provide records for the last 18 months of data. Vessel shall have the OCM manufacturer technician rep. provide records for the last 18 months.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2012
Resolution: Vessel provided tech rep from OWS/OCM manufacturer who attested to proper operation of OWS/OCM and provided 18 months of data. In addition the tech rep provided training to cheif engineer and crew on the proper operation of both devices.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 January 2012 Resolved
During review of the ORB the PSCO noted inconsistencies reguarding the sludge tank recorded weekly retention soundings (ORB Code 11.3) on Jan 22, 2012 when conpaired to the mehtods of disposal. Collectively a total of 2.57 cubic meters was not being record. PSC requestes SMS audit and a copy of the audit to be provided to USCG, FLAG, and Company with in 30 Days.
Condition: Invalid
Due 29 February 2012
Resolved 2 March 2012
Resolution: Recieved RINA SMS audit report.

Ownership record