Records from 2011 to 2017. Most recent: inspection, 29 March 2017.
Inspection history · 5
29 March 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6113895
7 February 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6083973
17 January 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794286
25 February 2011
ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3948121
24 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3948340
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 January 2016
Resolved
0720 - Fire Fighting - Firefighting protection systems, and fire fighting systems and appliances shall be maintained ready for use. PSCO discovered a quick closing valve for the MGO service tank blocked open, rendering the valve inoperative. 74 SOLAS am II-2/14.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2016
Resolved 21 January 2016
Resolution: Received class report from [name withheld] stating the outstanding deficiency has been rectified. See narrative for details.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 January 2016
Resolved
2540 - Emergency preparedness - A ship is subject to control when there are clear grounds for believing that the master/crew are not familiar with essential shipboard procedures. When asked to provide inventory list for free fall life boat, 3/O entered the free fall life boat and pulled the release. 74 SOLAS am XI-1/4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2016
Resolved 21 January 2016
Resolution: Received class report from Lloyd's Register and Liberia flag report stating the outstanding deficiency has been rectified. See narrative for details.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 17 January 2016
Resolved
0720 - Fire Fighting - Fire Fighting protection system, and fire fighting systems and appliances shall be maintained ready for use. PSCO observed the fire extinguisher outside the engine control room, showing low pressure and the 135 l fire extinguisher near the lower forward engine room badly corroded. 74 SOLAS am II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 21 January 2016
Resolution: Received class report from [name withheld] stating the outstanding deficiencies has been rectified. See narrative for details.
Lifesaving › Rescue Boat › Propulsion Starting System
Issued 25 February 2011
Resolved
0615 - Rescue Boats - Before the ship leaves port and at all times during the voyage, all lifesaving equipment shall be in working order and ready for immediate use. PSCO observed that the rescue boat would not start due to lack of fuel. - SOLAS 74a III/20
Action required: 705 - Other - as specified
Due 25 February 2011
Resolved 4 March 2011
Resolution: 04 Mar 2011- recieved class report attesting to proper corrections of fuel onboard for rescue boat.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 February 2011
Resolved
0696 - Record of inspections/maintenance - Maintenance, testing, and inspections of life-saving appliances shall be carried out in a manner having due regard ensuring reliability of such appliances. PSCO observed that the maintenance checklists for the rescue boat does not include a check for the fuel level of the rescue boat. - SOLAS 74a III/20
Action required: 705 - Other - as specified
Due 5 March 2011
Resolved 4 March 2011
Resolution: 04 Mar 2011- Recieved class report attesting to proper corrections to rescue boat check list