HONG KONG SPIRIT

HONG KONG SPIRIT is a 2011 freight ship. The Coast Guard has recorded 5 inspections since 2017, most recently in July 2020, along with 6 deficiencies and 1 operational control.

Records from 2017 to 2020. Most recent: inspection, 21 July 2020.

Built
2011
Last inspected
21 July 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 July 2020
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2017–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9587166
V7A2270
1106564
Flag
MALTA
Maury page id
psix-1106564

Documentation record

Tonnage as PSIX records it32476 - Dead Weight, Ton
41748 - Displacement, Ton
20867 - Convention (Subpart B), Gross Ton
11821 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

21 July 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7003386
19 July 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7009910
7 May 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6949633
4 May 2020 In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6947795
25 September 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6274466

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2020 Resolved
07126- oil accumulation in the engine room- Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaking from the top of the #1 generator fuel oil filter. Vessels crew rectified while PSCO was still onboard. SOLAS 74 (2014) II-2/4.1.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 July 2020
Resolution: Vessels crew tightened loose valve on top of fuel oil filter.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 July 2020 Resolved
07126- oil accumulation in the engine room- The arrangements for the storage, distribution, and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons on board. PSCO observed two open buckets of lubricating oil inside the ships fuel purifier room. SOLAS 74 (2014) II-2/4.2.3.1 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 21 July 2020
Resolution: Vessels crew removed buckets from purifier room.
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 September 2017 Resolved
CODE: 0750 CITE: 74SOLAS(14)II-2/4.2.2.3.4 ACTION: 30abc OIL FUEL PIPES, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM STORAGE /SETTLING/DAILY SERVICE TANK HAVING CAPACITY OF 500L & ABOVE SITUATED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON TANK CAPABLE OF BEING CLOSED FROM SAFE POSITION OUTSIDE THE SPACE IN THE EVENT OF A FIRE OCCURRING IN SPACE WHERE TANKS ARE SITUATED. QUICK CLOSING ISO VALVES FOR TANK LABELED HFO TO M/E HELD IN OPEN POSITION & COULD NOT OPERATE AS DESIGNED.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 September 2017
Resolution: See class report in documents
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 September 2017 Resolved
CODE: 0750 CITE: 74SOLAS(14)II-2/4.2.2.3.4 ACTION:30abc OIL FUEL PIPES, IF DAMAGED, WOULD ALLOW OIL TO ESCAPE FROM STORAGE /SETTLING/DAILY SERVICE TANK HAVING CAPACITY OF 500L & ABOVE SITUATED ABOVE THE DOUBLE BOTTOM, SHALL BE FITTED WITH A COCK OR VALVE DIRECTLY ON TANK CAPABLE OF BEING CLOSED FROM SAFE POSITION OUTSIDE THE SPACE IN THE EVENT OF A FIRE OCCURRING IN SPACE WHERE TANKS ARE SITUATED. QUICK CLOSING ISO VALVES FOR TANK LABELED LSFO TO M/E HELD IN OPEN POSITION & COULD NOT OPERATE AS DESIGNED.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 September 2017
Resolution: See class report in documents
Operations/Management › Pollution › Other MARPOL Annex VI Deficiencies
Issued 25 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 September 2017
Resolution: See class report in documents
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 25 September 2017 Resolved
CODE:1410 CITE: 74SOLAS(l4)I/lla ACTION: 60ac THE CONDITION OF THE SHIP & ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. MAIN ENGINE FAILS TO OPERATE ON LOW SULPHUR FUEL OIL.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 September 2017
Resolution: See class report in documents