MAURY USCG vessel records
← All vessels

ADVANTAGE SPRING

ADVANTAGE SPRING is a 2010 tank ship. The Coast Guard has recorded 9 inspections since 2016, most recently in July 2025, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 11 July 2025.

Built
2010
Last inspected
11 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 July 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9466582
1106578
Flag
MARSHALL ISLANDS
Maury page id
psix-1106578

Documentation record

Tonnage as PSIX records it84157 - Convention (Subpart B), Gross Ton
49031 - Convention (Subpart B), Net Ton
182538 - Displacement, Metric Ton
156596 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

11 July 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8183316
8 August 2024 PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7974992
6 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7975611
18 March 2022 COC-TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7409366
1 April 2020 COC-TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6932868
22 January 2019 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6610962
6 September 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6249596
14 August 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5970522
12 August 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5970949

Deficiency record · 3

Deck/Cargo › Inert Gas System › IGS Blower
Issued 6 September 2017 Resolved
1860; 60(a)(c); 74SOLAS(14)II-1/4.5.5.1.1 FSS CODE 15.2.3.1.6.1; THE PROTECTIONS OF THE CARGO TANKS SHALL BE ACHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE CODE TO PREVENT FLUE GAS LEAKAGES INTO ENCLOSED SPACES. BLOWER #2 WAS LEAKING FLUE GAS INTO THE ENCLOSED SPACE IN WHICH IT WAS HOUSED.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2017
Resolution: Received and reviewed class report from DNV-GL attesting to replacement of the blower seal and found fully operational after testing.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 6 September 2017 Resolved
1836;74SOLAS(140II-1/4.5.5.1.1 FSS CODE 15.2.3.1.3.1; 60(a)(c); THE PROTECTIONS OF THE CARGO TANKS SHALL BE ACHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE CODE. MEANS SHALL BE FITTED WHICH WILL EFFECTIVELY COOL THE VOLUME OF GAS. THE COOLING WATER ARRANGEMENTS SHALL BE SUCH THAT A SUPPLY OF WATER WILL ALWAYS BE AVAILABLE. INERT GAS SYSTEM COOLING SUPPLY LINE WAS LEAKING WATER.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 September 2017
Resolution: Received and reviwed class report from DNV-GL attesting to the repair cooling supply line to the scrubber tower.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 14 August 2016 Resolved
Original Flag State Endorsement must be kept onboard the ship on which the holder is serving. Master, Chief Engineer, Third Officer and Third Engineer are missing original Flag State Endorsements despite multiple requests made by the master. Scanned copies of valid Flag State Endorsements are onboard. STCW 1978, 2011 Edition. CH. I, Reg. I/2.11
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 16 August 2016
Resolution: Origional documents onboard as of 08/16/2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.