VELA

VELA is a 2009 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in April 2025, along with 14 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 30 April 2025.

Built
2009
Last inspected
30 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 April 2025
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9406180
1106591
Flag
LIBERIA
Maury page id
psix-1106591

Documentation record

Tonnage as PSIX records it41225 - Convention (Subpart B), Gross Ton
68720 - Displacement, Metric Ton
50420 - Dead Weight, Metric Ton
24035 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

30 April 2025 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8124028
6 March 2025 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8087959
3 March 2025 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8087099
28 February 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8086077
20 May 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5881924

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 March 2025 Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed air leak coming from CO2 bottle #60 hose connection to distribution line. 74 SOLAS(20)II-2/14.2.1.2 Code 17 abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: crew tightened connection and secured leak. Service air line was disconnected from main CO2 discharge line.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak from the fuel injectors on the M/E cylinder #6. 74SOLAS(09)II-2/4.1.1 Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Crew replaced and cleaned fuel injector
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak from the fuel injectors on the M/E cylinder #5. 74SOLAS(09)II-2/4.1.1 Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Crew replaced and cleaned fuel injector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2025 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed soft patch and leak from the aft LT cooler sea water outlet pipe. 74 SOLAS(04)II-1/26.1 Code 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2025 Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed soft patch and leak from the forward LT cooler sea water inlet pipe. 74 SOLAS(04)II-1/26.1 Code 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 March 2025 Resolved
The construction and means for securing the weather tightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. PSCO observed multiple ventiliation covers not able to be secured weather tight for cargo holds 4,5, and 6. ICLL(88)14.1 Code ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed minor leakage of fuel oil from the M/E cylinder #1 fuel oil pump. 74SOLAS(09)II-2/4.1.1 Code 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2025
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed minor leakages of fuel oil from A/E #3 fuel pumps. 74SOLAS(09)II-2/4.1.1 Code 17ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2025
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 February 2025 Resolved
The construction and means for securing the weathertightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 & 16 of this annex. PSCDO observed multiple ventilation covers that could not close in cargo holds 3,4,5, and 6. ICLL (88) 14.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 3 March 2025
Resolution: Sector VA received DNV Class Survey Statement requiring repairs by 30APR25.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 February 2025 Resolved
Surfaces with temperatures above 220° C which may be impinged as a result of a fuel system failure shall be properly insulated. PSCDO observed heavily saturated lagging on steam piping beneath cylinders 2,3,4 on main propulsion engine. 74 SOLAS(09) II-2/4.2.2.6.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Renewed damaged insulation to satisfaction of class surveyor and attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 February 2025 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids… means shall be provided to control leaks of flammable liquids. PSCDO observed significant oil pooling around aux generators 3, 4. Additionally, generator 3 oil strainer was observed to have a catch basin beneath it. 74 SOLAS (09) II-2/4.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Oil pooling and catch basins were removed in vicinity of #3,4 Gens to satisfaction of class surveyor and attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2025 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed… PSCDO observed improperly spliced wiring in the transformer room. 74 SOLAS (04) II-1/45.1.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2025
Resolution: Wire spliced in xformer room relocated into proper junction box to satisfaction of class surveyor and attending PSCO.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 February 2025 Resolved
The Oil Record Book Part 1 shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship (5) bunkering of fuel or bulk lubricating oil. PSCDO observed missing ORB entries for the last two bunkering operations. MARPOL I/17.2.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 February 2025
Resolution: C/E documented missing entries in ORB.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 February 2025 Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant dues and regulations established by the company. The technical nature of the deficiencies 1, 2, and 3 provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit satisfactory to the OCMI must be submitted within three months. 74 SOLAS (20) IX/3.1 ISM Part A/10.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to completed audit.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.