Records from 2016 to 2025. Most recent: inspection, 30 April 2025.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 March 2025
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed air leak coming from CO2 bottle #60 hose connection to distribution line.
74 SOLAS(20)II-2/14.2.1.2
Code 17 abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: crew tightened connection and secured leak. Service air line was disconnected from main CO2 discharge line.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak from the fuel injectors on the M/E cylinder #6.
74SOLAS(09)II-2/4.1.1
Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Crew replaced and cleaned fuel injector
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leak from the fuel injectors on the M/E cylinder #5.
74SOLAS(09)II-2/4.1.1
Code 17abc
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2025
Resolution: Crew replaced and cleaned fuel injector
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2025
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed soft patch and leak from the aft LT cooler sea water outlet pipe.
74 SOLAS(04)II-1/26.1
Code 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2025
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed soft patch and leak from the forward LT cooler sea water inlet pipe.
74 SOLAS(04)II-1/26.1
Code 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 March 2025
Resolved
The construction and means for securing the weather tightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. PSCO observed multiple ventiliation covers not able to be secured weather tight for cargo holds 4,5, and 6.
ICLL(88)14.1
Code ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed minor leakage of fuel oil from the M/E cylinder #1 fuel oil pump.
74SOLAS(09)II-2/4.1.1
Code 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2025
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed minor leakages of fuel oil from A/E #3 fuel pumps.
74SOLAS(09)II-2/4.1.1
Code 17ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 March 2025
Resolution: Received class report attesting to repairs.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 February 2025
Resolved
The construction and means for securing the weathertightness of cargo and other hatchways in position 1 and 2 shall be at least equivalent to the requirements of regulations 15 & 16 of this annex. PSCDO observed multiple ventilation covers that could not close in cargo holds 3,4,5, and 6.
ICLL (88) 14.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 3 March 2025
Resolution: Sector VA received DNV Class Survey Statement requiring repairs by 30APR25.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 February 2025
Resolved
Surfaces with temperatures above 220° C which may be impinged as a result of a fuel system failure shall be properly insulated. PSCDO observed heavily saturated lagging on steam piping beneath cylinders 2,3,4 on main propulsion engine.
74 SOLAS(09) II-2/4.2.2.6.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Renewed damaged insulation to satisfaction of class surveyor and attending PSCO.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 February 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids… means shall be provided to control leaks of flammable liquids. PSCDO observed significant oil pooling around aux generators 3, 4. Additionally, generator 3 oil strainer was observed to have a catch basin beneath it.
74 SOLAS (09) II-2/4.1.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2025
Resolution: Oil pooling and catch basins were removed in vicinity of #3,4 Gens to satisfaction of class surveyor and attending PSCO.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2025
Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed… PSCDO observed improperly spliced wiring in the transformer room.
74 SOLAS (04) II-1/45.1.1
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2025
Resolution: Wire spliced in xformer room relocated into proper junction box to satisfaction of class surveyor and attending PSCO.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 February 2025
Resolved
The Oil Record Book Part 1 shall be completed on each occasion, on a tank-to-tank basis if appropriate, whenever any of the following machinery space operations takes place in the ship (5) bunkering of fuel or bulk lubricating oil. PSCDO observed missing ORB entries for the last two bunkering operations.
MARPOL I/17.2.5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 February 2025
Resolution: C/E documented missing entries in ORB.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 28 February 2025
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant dues and regulations established by the company. The technical nature of the deficiencies 1, 2, and 3 provide objective evidence of a serious failure of the implementation of the ISM code. An internal audit satisfactory to the OCMI must be submitted within three months.
74 SOLAS (20) IX/3.1
ISM Part A/10.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2025
Resolution: Recieved satisfatory class report attesting to completed audit.