INDEPENDENT QUEST is a 2005 freight ship. The Coast Guard has recorded 18 inspections since 2020, most recently in February 2026, along with 7 deficiencies and 2 operational controls.

Records from 2020 to 2026. Most recent: inspection, 25 February 2026.

Built
2005
Last inspected
25 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9246700
1106593
Flag
PORTUGAL
Maury page id
psix-1106593

Documentation record

Tonnage as PSIX records it41743 - Dead Weight, Metric Ton
57251 - Displacement, Metric Ton
35881 - Convention (Subpart B), Gross Ton
14444 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

18 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

25 February 2026 PSC B · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8313731
28 January 2026 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8303050
29 July 2025 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8197199
6 November 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8031177
24 April 2024 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7900574
25 October 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7814016
11 April 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7666325
8 March 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7647734
14 February 2023 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7636419
13 December 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7608673
2 August 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7522748
5 July 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7496620
7 June 2022 Deficiency Check · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7470666
19 January 2022 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7382636
23 November 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7356269
29 September 2021 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7322906
11 May 2021 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7193715
27 October 2020 PSC A
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7085027

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 25 February 2026 Resolved
The purpose of this regulation is to maintain and monitor the effectivness pf the fire safey measures the ship is provided with. for this purpose, the following functional requirements shall be met; fire protection systems and fire fighting systems and appliances shall be maintained and ready for use. / PSCO observed 10 CO2 cylinders with cotter pins in stalled on manual side of system 74SOLAS(09) II-2/Reg 14.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 25 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2023 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be a design and construction adequate for the service for which they are intended. Vessels cooling jacket bolts are improperly installed with additional washers which is not in accordance with manufacturers recommendations. 74SOLAS(04)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2023
Resolution: Class report included repairs for removed copper washer shown in documents tab. No further action required.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 14 February 2023 Resolved
Before a ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Ships rescue boat had active leaking from drive shaft housing and not providing sufficient cooling to the outboard motor. 74SOLAS(20)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2023
Resolution: Repairs were made and found satisfactory during examination.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 February 2023 Resolved
Sewage system must be operated and maintained in accordance with the manufacturers instruction. PSCO identified 2 inch hole on the top of the sewage treatment plant. 33CFR159.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2023
Resolved 15 February 2023
Resolution: Class report included repairs for holed/wasted area shown in documents tab. No further action required.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 June 2022 Resolved
To prevent the ignition of combustible materials of flammable liquids: means shall be provided to control leaks of flammable liquids. Oil accumulation in engine room and oil pooled under #2, 3, 4 main engine cylinder heads. 74 SOLAS(04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Class confirmed repairs to their satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 7 June 2022 Resolved
To prevent the ignition of combustible materials of flammable liquids: means shall be provided to control leaks of flammable liquids.Insulation wtted through (oil) for #2,3,4 generators. 74 SOLAS(04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2022
Resolution: Class confirmed repairs to their satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 November 2021 Resolved
All items of rescue boat equipment shall be secured within the rescue boat. PSCO observed that all of the rescue boat inventory was stored in an adjacent locker, separate from the boat.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 November 2021
Resolution: Safety Officer returned all rescue boat inventory to the rescue boat equipment compartment.

Ownership record