← All vessels
T MATTERHORN
T MATTERHORN is a 2010 tank ship. The Coast Guard has recorded 13 inspections since 2011, most recently in July 2023, along with 9 deficiencies and 1 operational control.
Records from 2011 to 2023. Most recent: inspection, 15 July 2023.
- Built
- 2010
- Last inspected
- 15 July 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9555292 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EYC5
1106658
Flag
PANAMA
—
Maury page id
psix-1106658
Inspections, by type
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28777 - Regulatory (Subpart C or D), Gross Ton
28777 - Convention (Subpart B), Gross Ton
12680 - Convention (Subpart B), Net Ton
12680 - Regulatory (Subpart C or D), Net Ton
47981 - Dead Weight, Ton
58000 - Displacement, Ton
28777 - Convention (Subpart B), Gross Ton
12680 - Convention (Subpart B), Net Ton
12680 - Regulatory (Subpart C or D), Net Ton
47981 - Dead Weight, Ton
58000 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
15 July 2023
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7742682
25 January 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7627189
18 June 2022
COC-TVE Annual · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7476593
7 August 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7292434
26 June 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7236439
12 June 2021
PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7220917
7 June 2019
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6706553
21 November 2018
Ballast Water Examination · Deficiency Check · COC-TVE Renew · Administrative Inspection · COE-Dockside · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6581135
11 September 2017
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6263065
7 November 2016
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6037147
21 May 2014
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4862250
21 January 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3930803
17 January 2011
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3927778
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 26 June 2021
Resolved
FIRE FIGHTING SYSTEMS SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILIBLE FOR IMMEDIATE USE. FIRE CONTROL PANEL INOPERABLE.
74 SOLAS (09) II-2 14.2.1.2 ACTION tAKEN: 50 a/c
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 12 June 2021
Resolved
Oil residue may be disposed of directly from the oil residue tanks to reception facilities or through any other approved means of disposal. PSCO observed evaporation entries in the ORB as a means of disposal but was not documented in item 3.2 of the supplement to IOPP certificate form A/B.
MARPOL I/12.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2021
Resolved
In tankers, electrical equipment, cables, and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO found 05 explosion proof light fixtures with loose or missing hardware in the cargo pump room.
74SOLAS(20)II-1/45.11
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 November 2018
Resolved
Cargo ships where the horizontal distance from the extreme end of the stern or stem of the ship to the nearest end of the closest survival craft is more than 100 meters shall carry, in addition, a liferaft stowed as far forward or aft. During extreme weather, the liferaft on the bow accidentally inflated, requiring maintenance and service to be re-packed into container. SOLAS 74 (2014)CH III/31.1.9
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 November 2018
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The water spray systems on the motor lifeboats did not work when fresh water was introduced to the system for flushing. SOLAS 74 (2014) CH III/REG 20.2
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 November 2018
Resolved
A lifeboat which has a water spray fire-protection system shall be arranged for flushing with fresh water and allowing complete drainage. When fresh water was attached for flushing, not all the nozzles were being properly flushed and water only came out of one nozzle. SOLAS 74 (2014) CH III/ REG 31.1.7 LSA 4.9.2.3
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 November 2018
Resolved
Every lifeboat shall consist of food rations for each person the lifeboat is permitted to accomodate, these rations shall be kept in airtight packaging. Two out of 25 required rations on the port side lifeboat do not have airtight seal. 74 SOLAS (14) III/REG 34 LSA 4.4.8.12
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 November 2018
Resolved
Oil tankers shall carry fire-protected lifeboats which have a water spray fire-protection system that has arrangements for flushing with fresh water and allowing complete drainage. port and starboard lifeboats are fire-protected, however the female threaded pipe allowing for fresh water hose connection is bent from original design, which will prevent hose connection. 74 SOLAS (14) III / REG 31.1.7 LSA 4.9.2
Lifesaving › Immersion Suits › Serviceable
Issued 17 January 2011
Resolved
0663; Immersion suits complying with the requirements of section 2.3 of the code, of an appropriate size. Suits on board are too large for some of the crew. Company must provide adequate sizes for safety of the crew, 70-A/B.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.