TRADE is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2018, most recently in May 2024, along with 9 deficiencies and 1 operational control.
Records from 2018 to 2024. Most recent: inspection, 10 May 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it32287 - Convention (Subpart B), Gross Ton 19458 - Convention (Subpart B), Net Ton 67802 - Displacement, Metric Ton 58096 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 12
10 May 2024PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7906262
21 December 2022Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7611656
18 July 2022Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7510315
17 July 2022Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7508889
15 July 2022Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507572
22 March 2022Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7416389
23 July 2020Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7014117
22 June 2020Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6983957
26 May 2020PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6955799
16 April 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6939966
2 April 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6934744
9 January 2018PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6329658
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the authorized ballast water management methods listed in 33 CFR 151.2025(a). Vessel’s ballast water management system is inoperable. Vessel has been granted an extraordinary circumstance to employ the ballast water management method listed in 33 CFR 151.2025(a)(3) to conduct cargo operations while in the Sector New Orleans COTP Zone. In accordance with 33 CFR 151.2040(b)(3), the vessel must discharge only that amount of ballast water operationally necessary to ensure the safety and stability of the vessel for cargo operations.
33 CFR 151.2025
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 December 2022
Resolution: RCVD reviewed and accepted BV class report stating the BWTS is repaired.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 May 2020Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such as to ensure the safety of the ship and persons onboard. PSCO discovered a funnel and drip channel constructed with gasket material between cylinder #3 & #4 on the Main Diesel Eng collecting oil into a bucket from unidentified oil leak. 74SOLAS(14) I-2/4.2.3.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2020
Resolved 10 June 2020
Resolution: SEC NOLA received, reviewed and accepted class report from BV clearing the deficiency.
0750-Fire Prevention-PSCO observed excessive leakage from all three auxiliary engines IWO fuel pump casings, fuel pooling in catchment which was not regularly monitored and leaking down engine body. Additionally, excessive leaking was identified to turbocharger oil lubricated bearings. SOLAS 74 (09) a. II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. The class report stated:Three auxiliary engines and their turbochargers necessary overhaul (thread tightening and gaskets/ 0-rings replacement) was carried out.
1530-Radar-PSCO observed X-band radar inoperable since 04 December 17 and under repair. Vessel failed to request deviation IAW 33 CFR 164.53. SOLAS 74 (09) a. II-2/4.1.1
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. Furuno (maker's) rep attended the ship on Jan 9, 2018 and carried out X-band radar repairs;
repair report available. Radar tested by the undersigned satisfactorily.
0750-Fire Prevention-PSCO'S observed active fuel leaks IWO MDE #3, #4 high pressure fuel pumps and fuel injectors. SOLAS 74 (09) a. II-2/4.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. The class report stated: #3 and #4 high pressure fuel pumps and injectors defective/ brittle 0-rings were replaced.MOE was tested DSAH and DSAS several times with no leaks
1740-Oil discharge monitor/control system-PSCO has reason to believe OCM is improperly operating, during operational test OCM read 0.0 PPM without change, and with last 5 operations showing 0.0 PPM average. Require technician report attesting to satisfactory operation of the OCM. MARPOL Annex I/14.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. The class report stated: Service technician attended the ship, made OCM calibration and confirmed satisfactory operation condition; calibration report available.
1671-Satellite EPIRB 406MHz/1.6Hz-PSCO observed hydrostatic release unit for
the EPIRB was expired. SOLAS 74 (14) a. III/9.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. The class report stated: Expired HRU had been replaced; new HRU expire date: Jan 2020.
0690-Line throwing apparatus-PSCO observed four expired line throwing appliances. SOLAS 74 (14) a. III/19
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 17 January 2018
Resolution: 17JAN18: Received class report from NKK, stating deficiency has been rectified. The class report stated: Expired HRU had been replaced; new HRU expire date: Jan 2020.
Operations/Management › Pollution › SECA
Issued 9 January 2018Resolved
2420-Change-over procedures-PSCO observed that vessel did not have written LSFO changeover procedures. MARPOL Annex Vl/14.6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 9 January 2018
Resolution: Chief engineer developed and produced LSFO changeover procedure.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.