MAURY USCG vessel records Sign in
← All vessels

GEMINI

GEMINI is a 2006 freight ship. The Coast Guard has recorded 13 inspections since 2011, most recently in March 2026, along with 5 deficiencies and 1 operational control.

Records from 2011 to 2026. Most recent: inspection, 8 March 2026.

Built
2006
Last inspected
8 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9376309 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1106946
Flag
LIBERIA
—
Maury page id
psix-1106946

Inspections, by type

…with no type recorded2
Years with a record 8 calendar years (2011–2026)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30807 - Convention (Subpart B), Gross Ton
18126 - Convention (Subpart B), Net Ton
55781 - Dead Weight, Metric Ton
64423 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

8 March 2026 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8322664
20 September 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7550653
4 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7550828
4 September 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7551119
24 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6819762
3 September 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6797857
2 September 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6801920
10 December 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6594757
8 December 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6320844
7 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6313202
17 November 2015 ISPS II Exam · Administrative Inspection · Deficiency Check · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5763376
10 February 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4241970
24 February 2011 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3942145

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 3 September 2019 Resolved
Piping shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to minimize any danger to persons on board, due regard being paid to other hazards. PSCO oserved two exhaust leaks from the exhaust pipe within the main engine compartment. PSCO also observed that the fresh water pump was leaking approximately 2 cubic meters of water per day into the bilge tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2019
Resolved 24 September 2019
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 September 2019 Resolved
Ballast water reporting requirements exist for each vessel bound for ports or places of the United States. All required information is to be sent to the Ballast Water Information Clearinghouse (NBIC). The vessel did not submit NBIC report within 6 hours of arrival. (33 CFR 151.2401 10c)
Action required: 10 - Deficiency Rectified
Due 3 September 2019
Resolved 3 September 2019
Fire Fighting › Fire Main › Condition
Issued 7 December 2017 Resolved
0440-Fire fighting systems and appliances shall be kept in good working order and readliy available for immediate use. The fire main on the main deck, amidship had a pencil sized hole leaking.74SOLAS(04)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2017
Fire Fighting › Means of Escape › Number
Issued 17 November 2015 Resolved
0999 EEBDs shall comply with the FSS Code. The EEBD shall have a service duration of 10 minutes. The EEBD located in the engine control room was empty and would not provide the required amount of air for an emergency escape. 74 SOLAS 14 II-2/13.3.4.1 FSS Code Ch. 3.2.2.3.1 17c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2015
Resolved 18 November 2015
Resolution: Received service report via e-mail attesting to full functionality of EEBD.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 November 2015 Resolved
0710 Fuel pipes which if damaged would allow oil to escape from storage tank having a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being secured from outside the space. While demonstrating the operation of the EDG's fuel tank quick closing valve, crew was unable to operate the valve for approx. 3 minutes due to corrosion. SOLAS 14 II-2/4.2.2.3.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2015
Resolved 17 November 2015
Resolution: Crew was able to demonstrate proper operation before end of exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.