Records from 2016 to 2026. Most recent: inspection, 17 July 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
17 July 2026
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8440380
14 July 2026
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8438362
1 June 2026
PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8383565
29 May 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8383376
4 April 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8341760
30 March 2026
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8333968
27 March 2026
PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333106
29 September 2025
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8241762
18 September 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8234700
23 June 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8165656
18 March 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8092368
10 March 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090850
10 March 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8091330
9 March 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090585
17 November 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8036019
15 November 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8033707
2 November 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7819100
6 August 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6774267
18 August 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6511764
14 June 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6444199
20 April 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6392411
23 February 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6360539
17 August 2017
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6243155
18 April 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6127707
19 April 2016
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5857339
24 February 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5820754
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids. For this purpose...means shall be provided to control leaks of flammable liquids. PSCO observed oil soaked lagging and oil accumulation on main engine.
74SOLAS(09) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2026
Resolution: PSCO observed oil soaked lagging had been replaced and oil accumulationn on main engine had been cleaned up.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2026
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society...PSCO observed missing packing material in cable transit of emergency generator switchboard.
74SOLAS(04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2026
Resolution: PSCO observed that all packing material had been replaced in emergency generator switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2026
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society...PSCO observed evidence of overheating of electrical panel for closed loop scrubber system. Crew installed portable fan next to control panel to prevent overheating.
74SOLAS(04) II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 June 2026
Resolution: PSCO observed that fan had been removed and there is no evidence of overheating.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed reversing magnetic switch junction box for M/E cylinder #8 secured by electrical tape and loose wiring.
74SOLAS(04)II-1/40.1.3 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 April 2026
Resolution: Received images showing rectification of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 30 March 2026
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subject. PSCO observed wasted steam supply pipe to HFO tank in purifier space.
74SOLAS(04)II-1/33.1 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 April 2026
Resolution: Received images showing rectification of the deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 March 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of deficiencies 02, 03, 04 and 05 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention.
74 SOLAS (2020) IX/ 3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 March 2026
Resolution: Audit completed by class, report uploaded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed tape around source of leak that was failing and actively flowing into a full bucket of oil. Upon identification crew added more tape and painted tape silver. Leak continued to be active in the presence of examiners after more tape/paint was applied.
74 SOLAS (2009) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 March 2026
Resolution: Observed under approx. 8 bar pressure with no leaks. Replacement part on order, order receipt uploaded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 March 2026
Resolved
Means of control for flammable liquids in the space shall be provided. PSCO observed improper stowage of various flammanble materials inside a void.
74 SOLAS (2009) II-2/5.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 March 2026
Resolution: All removed, reception facility receipt uploaded.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2026
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed flame detectors unable to activate properly per manufacturer's instructions. Crew then utilized an open flame to test flame dectectors.
74 SOLAS (2009) II-2/2.2.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 March 2026
Resolution: Class report identified SMS issue and training to be conducted. Verified FF testing logs. Class report uploaded.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed feed pump for HFO purifier slowly leaking oil.
74 SOLAS (2009) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 29 March 2026
Resolution: Verified HFO fuel purifier out order and not in use. Spare parts to replace seals order 20MAR26, uplaoded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2026
Resolved
Provision shall be made to facilitate cleaning, inspection, and maintenance of main propulsion... Means shall be provided to control leaks of flammable liquids. PSCO observed active leaks with failed attempts to rectify, showing lack of maintenance of main engine.
74 SOLAS (2004) II-1/26.7
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 March 2026
Resolution: Rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 18 September 2025
Resolved
The machinery, boilers and other pressure vessels, associated pipings and fittings shall be of design and construction adequate for the service inteded and shall be protected as to reduce danger to persons onboard. PSCO observed steam leak from auxiliary boiler condensate return pipe to cascade tank. Cascade tank low level alarm witnessed and functional.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2025
Resolved 29 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 18 September 2025
Resolved
After any survey of the ship has been completed, no change shall be made in the equipment, systems, fittings, arrangements without the sanction of the administration. PSCO observed MEPC(60) Oil Content Meter on IOPP Form A, MEPC(107) Oil Content Meter installed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2025
Resolved 29 September 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 September 2025
Resolved
Muster and embarkation station shall be adequately illuminated by lighting supplied from the emerfency source of electrical power required by regulation II-1/42 or II-1/43 as appropriate. PSCO observed Port and Stbd pilot lights and stbd side rescue boat embarkation lights were extinguished. Lights all replaced and verified by PSCO on the spot.
Action required: 10 - Deficiency Rectified
Due 18 September 2025
Resolved 18 September 2025
Resolution: Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2025
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with the effective means for its operation and control. PSCDO was informed that during departure, the vessel's engine failed to start.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 March 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-1/40.1.3
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED EXPOSED PANELING, MISSING COVERS, MULTIPLE BULBS INOPERABLE, GROUND WIRES MISSING, CRACKED DIGITAL DISPLAYS, THROUGHOUT THE ENGINE ROOM.
17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2024
Resolved 16 November 2024
Resolution: Class survey attests: exposed panels, missing covers, inoperable lightbulbs, missing ground wires, and cracked display were replaced or secured as applicable and verified in order.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 November 2024
Resolved 9 March 2025
Resolution: Sector NY conducted a PSC B exam on the vessel on 03/09/2025. Coast Guard personnel were able to verify repairs and vessel also provided a Class Report.
//s// [name withheld]/CWO2/SecNY
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/4.1.1
... TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS... MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED APPROXIMATELY 03 GALLONS ON THE TURBOCHARGER OF THE #3 MAIN ENGINE.
50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2024
Resolved 16 November 2024
Resolution: Class survey attests: The residual liquid from the previously repaired leakage was verified cleaned.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2024
Resolved
74 SOLAS 2020 I/11(a)
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS... FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED CORROSION TO THE EXHAUST DUCTING OF THE MAIN ENGINE WITH EVIDENCE OF A PREVIOUS LEAK.
50AC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 December 2024
Resolved 16 November 2024
Resolution: Class survey attests: The ducting was verified free of leakage and the affected ducting was ground and rewelded and verified in order.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-1/45.2
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS... WITHOUT DANGER TO PERSONNEL. PSCO OBSERVED BLOCKED ACCESS TO 440V SWITCHBOARD.
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2024
Resolved 15 November 2024
Resolution: CREW REMOVED BOOKCASE WHICH WAS BLOCKING ACCESS TO SWITCHBOARD.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/10.2.3.1.1
... EACH HOSE SHALL BE PROVIDED WITH A NOZZLE AND THE NECESSARY COUPLINGS... PSCO OBSERVED 03 MISSING NOZZLES AND 02 MISSING GASKETS FROM MULTIPLE FIRE HYDRANTS IN THE ENGINE ROOMS.
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2024
Resolved 15 November 2024
Resolution: REPLACED ALL MISSING NOZZLES.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/14.1.1
... FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED AND READY FOR USE. PSCO OBSERVED EXTINGUISHER IN ENGINE ROOM NOT PROPERLY SECURED.
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 November 2024
Resolved 15 November 2024
Resolution: CREW SECURED FIRE EXTINGUISHER IN ENGINE ROOM.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 August 2019
Resolved
The Administration shall satisft itself that the general strutural strength of hull is sufficient for draught corresponding to freeboard assigned. Several sharp insets observed on port bow IVO frame 90 at approximately 11m draught mark.
ICLL 1966 Reg 1
40A
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 6 August 2019
Resolved
Port side gangway top landing connection joint appears damaged and difficult to rotate. It makes metal on metal contact at the pivot point.
40A
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2019