← All vessels
MSC MAUREEN
MSC MAUREEN is a 2003 freight ship. The Coast Guard has recorded 27 inspections since 2014, most recently in July 2026, along with 24 deficiencies and 4 operational controls.
Records from 2014 to 2026. Most recent: inspection, 17 July 2026.
- Built
- 2003
- Last inspected
- 17 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9251717 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HPMP
1106952
Flag
PANAMA
—
Maury page id
psix-1106952
Inspections, by type
…with no type recorded4
Years with a record
9 calendar years (2014–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it75590 - Convention (Subpart B), Gross Ton
42233 - Convention (Subpart B), Net Ton
85810 - Dead Weight, Metric Ton
112639 - Displacement, Metric Ton
42233 - Convention (Subpart B), Net Ton
85810 - Dead Weight, Metric Ton
112639 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
17 July 2026
PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8440380
14 July 2026
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8438362
1 June 2026
PSC A · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8383565
29 May 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8383376
4 April 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8341760
30 March 2026
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8333968
27 March 2026
PSC B · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8333106
29 September 2025
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8241762
18 September 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8234700
23 June 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8165656
18 March 2025
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8092368
10 March 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090850
10 March 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8091330
9 March 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8090585
17 November 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8036019
15 November 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8033707
2 November 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7819100
6 August 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6774267
18 August 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6511764
14 June 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6444199
20 April 2018
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6392411
23 February 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6360539
17 August 2017
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6243155
18 April 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6127707
19 April 2016
PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5857339
24 February 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5820754
29 October 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5014177
Deficiency record · 24
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 June 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids. For this purpose...means shall be provided to control leaks of flammable liquids. PSCO observed oil soaked lagging and oil accumulation on main engine.
74SOLAS(09) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2026
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society...PSCO observed missing packing material in cable transit of emergency generator switchboard.
74SOLAS(04) II-1/3-1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2026
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society...PSCO observed evidence of overheating of electrical panel for closed loop scrubber system. Crew installed portable fan next to control panel to prevent overheating.
74SOLAS(04) II-1/3-1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed reversing magnetic switch junction box for M/E cylinder #8 secured by electrical tape and loose wiring.
74SOLAS(04)II-1/40.1.3 40ac
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 30 March 2026
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stresses to which it may be subject. PSCO observed wasted steam supply pipe to HFO tank in purifier space.
74SOLAS(04)II-1/33.1 40ac
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 March 2026
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The technical and/or operational nature of deficiencies 02, 03, 04 and 05 provide objective evidence of a serious failure, or lack of effectiveness, of the implementation of the ISM Code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention.
74 SOLAS (2020) IX/ 3.1 ISM Code 10.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed tape around source of leak that was failing and actively flowing into a full bucket of oil. Upon identification crew added more tape and painted tape silver. Leak continued to be active in the presence of examiners after more tape/paint was applied.
74 SOLAS (2009) II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 March 2026
Resolved
Means of control for flammable liquids in the space shall be provided. PSCO observed improper stowage of various flammanble materials inside a void.
74 SOLAS (2009) II-2/5.1.2
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2026
Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed flame detectors unable to activate properly per manufacturer's instructions. Crew then utilized an open flame to test flame dectectors.
74 SOLAS (2009) II-2/2.2.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 March 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed feed pump for HFO purifier slowly leaking oil.
74 SOLAS (2009) II-2/4.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2026
Resolved
Provision shall be made to facilitate cleaning, inspection, and maintenance of main propulsion... Means shall be provided to control leaks of flammable liquids. PSCO observed active leaks with failed attempts to rectify, showing lack of maintenance of main engine.
74 SOLAS (2004) II-1/26.7
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 18 September 2025
Resolved
The machinery, boilers and other pressure vessels, associated pipings and fittings shall be of design and construction adequate for the service inteded and shall be protected as to reduce danger to persons onboard. PSCO observed steam leak from auxiliary boiler condensate return pipe to cascade tank. Cascade tank low level alarm witnessed and functional.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 18 September 2025
Resolved
After any survey of the ship has been completed, no change shall be made in the equipment, systems, fittings, arrangements without the sanction of the administration. PSCO observed MEPC(60) Oil Content Meter on IOPP Form A, MEPC(107) Oil Content Meter installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 September 2025
Resolved
Muster and embarkation station shall be adequately illuminated by lighting supplied from the emerfency source of electrical power required by regulation II-1/42 or II-1/43 as appropriate. PSCO observed Port and Stbd pilot lights and stbd side rescue boat embarkation lights were extinguished. Lights all replaced and verified by PSCO on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 March 2025
Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with the effective means for its operation and control. PSCDO was informed that during departure, the vessel's engine failed to start.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-1/40.1.3
ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED EXPOSED PANELING, MISSING COVERS, MULTIPLE BULBS INOPERABLE, GROUND WIRES MISSING, CRACKED DIGITAL DISPLAYS, THROUGHOUT THE ENGINE ROOM.
17AC
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 November 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/4.1.1
... TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS... MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED APPROXIMATELY 03 GALLONS ON THE TURBOCHARGER OF THE #3 MAIN ENGINE.
50AC
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 November 2024
Resolved
74 SOLAS 2020 I/11(a)
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS... FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED CORROSION TO THE EXHAUST DUCTING OF THE MAIN ENGINE WITH EVIDENCE OF A PREVIOUS LEAK.
50AC
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-1/45.2
MAIN AND EMERGENCY SWITCHBOARDS SHALL BE SO ARRANGED AS TO GIVE EASY ACCESS... WITHOUT DANGER TO PERSONNEL. PSCO OBSERVED BLOCKED ACCESS TO 440V SWITCHBOARD.
10C
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/10.2.3.1.1
... EACH HOSE SHALL BE PROVIDED WITH A NOZZLE AND THE NECESSARY COUPLINGS... PSCO OBSERVED 03 MISSING NOZZLES AND 02 MISSING GASKETS FROM MULTIPLE FIRE HYDRANTS IN THE ENGINE ROOMS.
10C
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 November 2024
Resolved
74 SOLAS 2020 II-2/14.1.1
... FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE MAINTAINED AND READY FOR USE. PSCO OBSERVED EXTINGUISHER IN ENGINE ROOM NOT PROPERLY SECURED.
10C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 August 2019
Resolved
The Administration shall satisft itself that the general strutural strength of hull is sufficient for draught corresponding to freeboard assigned. Several sharp insets observed on port bow IVO frame 90 at approximately 11m draught mark.
ICLL 1966 Reg 1
40A
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 6 August 2019
Resolved
Port side gangway top landing connection joint appears damaged and difficult to rotate. It makes metal on metal contact at the pivot point.
40A
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.