← All vessels
CAUNEQ
CAUNEQ is a 2011 tank barge. The Coast Guard has recorded 25 inspections since 2012, most recently in February 2026, along with 27 deficiencies — 2 with no resolution recorded —.
Records from 2012 to 2026. Most recent: inspection, 6 February 2026.
- Built
- 2011
- Last inspected
- 6 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1231400
1106953
Flag
UNITED STATES
—
Maury page id
psix-1106953
Inspections, by type
…past their stated due date2
Years with a record
15 calendar years (2012–2026)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)154.7 ft × 44.5 ft × 6.0 ft
Registered tonnagegross 364 / net 361
ITC dimensions (L × B × D)154.7 ft × 44.5 ft × 6.0 ft
ITC tonnagegross 313 / net 190
BuilderU.S. BARGE LLC · PORTLAND, OR, UNITED STATES · built 2011
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBETHEL, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it257 - Displacement, Gross Ton
313 - Convention (Subpart B), Gross Ton
364 - Regulatory (Subpart C or D), Gross Ton
190 - Convention (Subpart B), Net Ton
361 - Regulatory (Subpart C or D), Net Ton
313 - Convention (Subpart B), Gross Ton
364 - Regulatory (Subpart C or D), Gross Ton
190 - Convention (Subpart B), Net Ton
361 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
6 February 2026
Appeal
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8317305
9 January 2026
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8294038
3 June 2025
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8097757
6 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7950956
10 June 2024
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7937400
31 October 2023
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7821187
27 July 2023
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7752261
14 July 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7478234
19 May 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7200164
19 April 2020
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6955533
2 October 2019
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6826626
24 May 2019
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6690962
22 May 2018
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6414577
24 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6226790
24 October 2016
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6028888
18 October 2016
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6024800
25 April 2016
COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5862082
30 July 2015
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5200960
23 July 2015
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5125066
5 December 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5035110
14 April 2014
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4871590
7 November 2013
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4749243
25 June 2013
Deficiency Check · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4613795
12 July 2012
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4398382
24 May 2012
Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4321834
Deficiency record · 27
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 January 2026
No resolution recorded
In hazardous areas machinery and electrical equipment must be approved for the installation by MSC. The
portable diesel engine driven cargo pump must be
approved for operation within the hazardous zone or modified to place the engine and electrical components outside the hazardous zone (10 ft). *Complete prior to operating in 2026.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 9 January 2026
No resolution recorded
On all tank vessels, the construction or conversion of which is started on or after July 1, 1951, the cargo piping shall be: A fixed cargo piping system shall be installed on a tank vessel carrying Grade A, B, or C cargo. A portable diesel engine-driven cargo pump is being utilized within a hazardous location, and portable cargo hoses are being used for cargo transfer operations. This arrangement does not comply with the regulatory requirements for hazardous area installations and fixed cargo piping systems on tank barges carrying Grade A, B, or C cargo. *Complete prior to operating in 2026.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 June 2025
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in § 31.10-17 (a) and (b) and your Certificate of Inspection must be endorsed. The Periodic Inspection was required to be completed by August 19, 2024 in order to maintain maintain the validity of the COI but the periodic inspection was not completed within the required time frame.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 3 June 2025
Resolved
The transfer procedures required by § 155.720 must be permanently posted or available at a place where the procedures can be easily seen and used by members of the crew when engaged in transfer operations. The oil transfer procedures were not on board and available for the crew.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 June 2025
Resolved
Electrical equipment should not be installed in hazardous locations unless essential for operational purposes. When installed in these locations, special precautions should be taken to ensure that the electrical equipment is not a source of ignition. Electrical equipment not rated for hazardous locations (not intrinsically safe or explosion-proof) was improperly used inside a conex box located within a hazardous area on deck. Power was supplied to this equipment via an extension cord.
46 CFR 32.45-1
46 CFR 111.105-3(a)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 June 2025
Resolved
Manholes and flush scuttles in position 1 or 2 or within superstructures other than enclosed superstructures shall be closed by substantial covers capable of being made watertight. The gaskets for the manholes hatches on the cargo domes were found wasted and not maintaining watertight integrity.
46 CFR 31.25-1
46 CFR 42.15-40
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2025
Resolved
A vessel being pushed ahead, not being part of a composite unit, shall exhibit at the forward end; sidelights. The portable sidelights were not operational.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 July 2024
Resolved
When minor repairs of tank vessels become necessary such work shall be under the direction of the Officer in Charge, Marine Inspection, and shall be in accordance with the regulations in effect at the time the vessel was contracted for or built, or in accordance with the regulations in effect for new construction insofar as possible. Vessel cargo pump soft start failed. Vessel is authorized temporary use of portable cargo pump outside of hazardous zone while awaiting permanent repair of existing cargo pump. 46CFR30.01-10
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 October 2023
Resolved
Vessel was reported beset in ice for three days in Kuskokwim River, until favorable tide change freed the barge. No damage was reported by operator, and the barge is schedule for two more deliveries (Village of Kasigluk and Nunapitchuk) before being laid up for the season. After making deliveries to the two listed villages, vessel is required to complete Internal Structural Exam prior to operating with Cargo. 31.10-21
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 July 2023
Resolved
09209 - The locations in the weather are Class I, Division 1 (Zone 1) locations (except the open deck area on an inorganic acid carrier which is considered a non-hazardous location) and may have only approved intrinsically safe, explosion proof, or purged and pressurized electrical equipment. Cargo pump motor is marked for use within Class I, Division 2. 46 CFR 111.105-31(l)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 27 July 2023
Resolved
06106 - The transfer procedures required by 33 CFR 155.720 must contain all the required items listed in 33 CFR 155.750. Vessel currently has a generic tankerman's manual that meets many of the requirements, but lacks barge specific items (e.g. description of the transfer, line diagrams, and cargo information). 33 CFR 155.750
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 July 2023
Resolved
01305 - The vessel operator shall keep a written record available for inspection by the COTP or OCMI of the date and result of the most recent test and inspection of each item tested or inspected as required by § 156.170 of this chapter. Pressure gauges on the discharge side of the cargo pumps did not have records of test indicating accuracy within 10 percent of the actual pressure. 33 CFR 155.820 / 33 CFR 156.170
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 27 July 2023
Resolved
09217 - A sign shall be displayed to warn persons approaching the gangway, while a vessel is moored or anchored unless it is empty and gas-freed. The sign shall state in letters not less than 2 inches high substantially as follows: Warning, No open lights, No smoking, No visitors. Vessel does not have the required sign as described in 46 CFR 35.30-1(b). 46 CFR 35.30-1(b)
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 July 2023
Resolved
01305 - If your vessel is greater than or equal to 300 gross tons, you must submit a signed and certified, complete and accurate NOI in accordance with the requirements of Appendix E to receive coverage under the vessel general permit. Vessel has not filed an NOI for this vessel. 2013 VGP 1.5.1.1
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 19 May 2021
Resolved
Complete satisfactory hydro test of cargo piping system.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 25 April 2016
Resolved
Provide proof of hydro-testing of cargo piping prior to conducting operations.
Electrical › Electrical Distribution System (service) › Switch
Issued 23 July 2015
Resolved
Provide new or properly repair Class 1 Div 1 cargo pump emergency shut down switch.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 23 July 2015
Resolved
Provide servicing report for all portable fire extinguishers.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 23 July 2015
Resolved
Provide hydrostatic test reports for all cargo hoses to be used in service, 1.5 times the MAWP.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 23 July 2015
Resolved
Update transfer procedures piping drawing to reflect currentl configuration.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 23 July 2015
Resolved
Provide containment under each oil loading manifold and transfer connections as required by 33 CGR 155.310
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 25 June 2013
Resolved
Provide three ullage opening flame screens for 4P, 5P, & 4S (46 CFR 35.30-10).
Lifesaving › Lifebuoys › Not on Board
Issued 25 June 2013
Resolved
Provide two ring life buoys mounted at each end of the barge marked with name & hailing port (46 CFR 199.640(i)(2)).
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 25 June 2013
Resolved
Install electrical non-conductive deck covering at front of switchboard (46 CFR 111.30-11).
Documentation › Logs/Records › Oil Record Book
Issued 25 June 2013
Resolved
Obtain & maintain oil record book part 1 & part 2 (33 CFR 151.25).
Personnel › Manning/Qualifications › Person in Charge (PIC) of Transfer
Issued 12 July 2012
Resolved
Provide current list of approved PIC's
Communications › Visual Communication › Red Warning Signal
Issued 12 July 2012
Resolved
Provide benzene regulated area stripe for barge.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National