Records from 2016 to 2026. Most recent: operational control imposed, 21 July 2026.
Inspection history · 37
21 July 2026
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8443495
16 April 2026
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8350498
17 October 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8254643
16 October 2025
PSC B · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8253787
16 October 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8254004
21 August 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219681
26 March 2025
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8100237
5 April 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890494
28 February 2024
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871068
19 January 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7623954
28 July 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7518867
17 March 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7157998
27 January 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7128398
20 July 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7010951
24 June 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6985374
23 May 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6958496
19 January 2020
Ballast Water Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6892251
14 November 2019
PII Safety Exam · ISPS III Exam · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6855352
19 July 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6754250
28 May 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6696712
13 May 2019
ISPS III Exam · Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6682765
13 November 2018
Deficiency Check · ISPS II Exam · CCSSC Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579405
16 May 2018
MTSA Verification · CCSSC Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6414713
29 November 2017
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6314671
16 November 2017
CCSSC Examination · ISPS III Exam · Deficiency Check · NPV Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6307921
17 May 2017
ISPS II Exam · CCSSC Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6145207
23 February 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6093188
7 February 2017
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 6084301
3 February 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6118149
27 October 2016
Ballast Water Examination · CCSSC Examination · MTSA/ISPS Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6027802
17 October 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6024076
26 April 2016
MTSA/ISPS Verification · Ballast Water Examination · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5862606
14 March 2016
COE-Offshore
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5832523
19 February 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5818446
18 February 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5817946
20 January 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5800165
14 January 2016
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5797195
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 16 October 2025
Resolved
"The owner or master of every ship to which this code applies should ensure that: the condition of the ship and its equipment is maintained to conform with the provisions of this code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment." PSCO observed the primary, and only, X-Band radar does not function past 3NM range, rendering the ship unable to detect vessels past 3NM.
CCSSC 1997 1.11.1
Code 16bc
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 October 2025
Resolved 7 November 2025
Resolution: Crew repaired the radar and provided flag documentation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2021
Resolved
Maintain a Ballast Water Management Plan that has been developed specifically for the vessel and allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. The plan must include - (1) detailed safety procedures... The Ballast Water Procedures...The Ballast Water Management Plan has no way to accurately calculate stability based on quantities retained the each tank.
33 CFR 151.2050(g)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 27 March 2021
Resolution: Drydock report submitted showing the sight glass installed on the BWT's under Flag Authority.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2021
Resolved
Certification of accurate information. Include the master, owner, operator, agent, person in charge, or responsible officer's.... attesting to the accuracy of the information.. in accordance with the Ballast Water Management Plan required by 33 CFR 151.2050 (g)... Ballast Water Record Book does not record latitude and longitude while at sea when operations are conducted, nor does the vessel record the capacity retained on board before any recirculating operation.
33 CFR 151.2050 (a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 6 May 2021
Resolution: SOP and Plan updated as Attested by Flag and Records verified by PSCO for correct recordings of Ballast.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 January 2021
Resolved
The Ballast Water Report required by paragraph (b) of this section must include the following information: Ballast Water Information. This includes the vessels total ballast water capacity... total volume of Ballast Water Onboard... Vessel's report of ballast water reported total ballast water capacity is 186m^3 when the total is actually 411 m^3. Vessel also declared 80 m^3 ballast water retained when there is no means to ascertain capacity.
33 151.2060(c)(3)
Action required: 10 - Deficiency Rectified
Due 27 January 2021
Resolved 27 January 2021
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 27 January 2021
Resolved
Life-Saving Appliances required by this chapter should comply with the technical specifications of LSA code... limit switch missing from rescue boat davit.
CCSSC 4.3.1
LSA Code 6.1.2.7
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2021
Resolved 25 February 2021
Resolution: Flag Attestation concerning the Pallinger Limit switch installation received.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2020
Resolved
A main source of electrical power of sufficient capacity to supply all those services... shall be provided. Vessels port side generator is non-operational and being supplemented by a temporary installation on deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2020
Resolved 24 June 2020
Resolution: Vessel provided through email Flag Attestation Letter and technicians service report dated June 11, 20 attesting to the proper operation of port side generator. New rigging and installation of Generator NO.1 85kw generator head was performed by tech.
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 14 November 2019
Resolved
All cargoes...shall be loaded, stowed and secured throughout the voyage in accordance with the Cargo Securing Manual approved by the administration. Palletized cargo on deck not protected against the elements as required by section 3.3.3 of the ship's Cargo Securing Manual. Additionally, cargo is stowed on parts of the deck that are marked as passageways.
74SOLAS(14CONS) CH. VI/Reg 5.6
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2019
Resolved 15 November 2019
Resolution: Operator provided satisfactory photos of protecting the cargo from the elements
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 14 November 2019
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book part I, so that all entries in the book appropriate to that operation is complete. Oil Record Book entry dated 08/22/19 report a quantity of 615 gallons in the ship's sludge tank. An entry dated 09/01/2019 records a transfer of 7 gallons into the tank with a total quantity retained of 1,113 gallons. There is no record of where the additional oily waste was transferred from. Additionally, a sounding of the sludge tank on 11/02/2019 shows a quantity of 1,380 gallons. Records reflect an off load of sludge to a Mobil facility of 1,200 gallons on 11/07/2019. An entry on 11/07/2019 to record the amount retained in the sludge tank says 0.0 gallons. There is nothing logged accounting for the remaining 180 gallons. MARPOL (17 Cons) Annex I/17.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 30 December 2019
Resolution: Vessel Submitted copies of oil record book with correct entries.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 14 November 2019
Resolved
...These requirements shall be recorded in form of record of ship equipment and information attached to the safety certificate. Vessel is equipped with a BNWAS. This equipment is currently inoperable and is not listed on any of the required certificates. CCSSC (2018) 6.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 25 November 2019
Resolution: Technician's report recieved. Equipment is fully operational. Flag amended the safety certificate to reflect presence of a BNWAS onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
In ships of 50M in length and over at least 02 lifebuoys provided with self-igniting lights shall also be provided with self-activating smoke signals. Each of these lifebuoys capable of quick release from the navigation bridge where practicable or be of the throwover type. Lifebuoys required with smoke and light are designed as throwover type however their arrangement; secured directly to the superstructure with railing separated at approximately 4 feet, prevents smoke and light from being discharged when lifebuoys are thrown as designed. CCSSC 4.12.3 16bc
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 28 May 2019
Resolution: Received an attestation letter from Panama Maritime Authority stating that new quick release life ring brackets were installed on the bridge wings.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 13 November 2018
Resolved
2120-Garbage-Every ship of 400 gross tonnage and above... shall be provided with a Garbage Record Book. The Garbage Record Book... shall be in the form specified in Appendix II to this Annex. Garbage Record Book is missing dates and signatures. Discharges of operational wastes are not being logged in the Rocord Book.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 21 November 2018
Resolution: Recieved evidence of garbage log training, updated garbage receipt forms, and a satisfactory garbage disposal record. Flag state attestation of deficiency accepted.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 16 November 2017
Resolved
Every Seafarer holding a certificate issued under the provisions of the Convention, who is serving at sea, shall also hold a valid medical certificate. Chief Engineer and 2nd Engineer had expired medical certificates. 02 Able Seamen did not have valid medical certificates. STCW Reg I/9.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 20 November 2017
Resolution: All four crew members needing medical exams where able to provide valid documents from a medical doctor listing them all as fit for duty.
Lifesaving › Launching Appliances › Davit
Issued 16 November 2017
Resolved
Rescue boates shall be stowed: In a state of continuous rediness for launching in not more than 5 min. While attempting to launch the rescue boat, the remote brake cable became tangled and the crew was not able to lower or raise the boat. CCSSC 4.9.8.1
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 16 November 2017
Resolution: Crew repaired remote brake and demonstrated proper launching and recovery of rescue boat.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 16 November 2017
Resolved
All new and existing vessels operating in area III and Unrestricted shall be provided with: An echo sounder. Echo Sounder would not provide accurate reading for the charted depth. CCSSC 6.4.4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 November 2017
Resolved 20 November 2017
Resolution: Echo Depth Sounder sensor was replaced and now produces an accurate read out.
Communications › Visual Communication › Signalling Lamp
Issued 16 November 2017
Resolved
All new and existing vessels operating in area III and Unrestricted shall be provided with: ALDIS lamp. ALDIS lamp battery would not hold a charge. CCSSC 6.4.4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 November 2017
Resolution: Replaced batteries for the stand alone power source for the signaling lamp.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 16 November 2017
Resolved
The certificate referred to in 1.12.1 shall be supplemented by a Record of Equipment and Ship Information which shall be permanently attached thereto. Record of equipment did not coincide with the Minimum Safe Manning document and had conflicting engine room manning designation. The Record of Equipment also had incorrect wattage to the engine power when compared to the EIAPP. CCSSC 1.12.1
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 29 November 2017
Resolution: Vessel sent in documentation resolving the deficiency
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 May 2017
Resolved
CCSSC Ch.3/Reg 3.13.2 - In all such ships fire control plans shall be kept up to date. Quantity of external fire suppression for paint locker is not documented on fire control plan.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 30 May 2017
Resolution: Vessel corrected Fire Control Plan to accurately reflect the external fire suppression for paint locker.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 17 May 2017
Resolved
MARPOL (2011 cons) Annex V/Reg10.3 - Every ship 400 gross tonnage and above shall be as the form in this appendix. Signature of officer in charge of operation is missing on 03 pages of the Garbage Record Book.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Deficiency rectified on site.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 17 May 2017
Resolved
CCSSC Ch.1/Reg1.11.1 - The ships equipment shall be maintained to ensure the ship will remain fit to proceed to sea without danger to ship, persons on board or the environment. Engine room starboard side smoke/heat detector is inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2017
Resolved 18 May 2017
Resolution: Vessel placed 02 operational heat detectors in the engineroom.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 October 2016
Resolved
01 - 1510 - Every compass shall be fitted with a compass designed for marine use. 15 degree variance between heading and bridge compass reading found. CCSSC 6.4.1
Action required: 705 - Other - as specified
Due 10 November 2016
Resolved 9 November 2016
Resolution: Received and reviewed flag attestation for the compass deficiency. All SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 27 October 2016
Resolved
02 - 1430 - A main source of electrical power of sufficient capacity to supply all electrical services necessary for maintaing the ship in normal operations shall be provided. STBD generator found inoperable. CCSSC 2.28
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2016
Resolution: Boarded vessel and ran starboard generator, viewed proper operation. Reviewed and accepted flag attestation and tech report attesting to the proper repair of the generator.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 October 2016
Resolved
03 - 0740 - CCSSC CHAP 3.3.10.1 AN EMERGENCY FIRE PUMP SHALL BE POSITIONED OUTSIDE THE ENGINE ROOM AND PERMANENTLY CONNECTED TO THE FIREMAINS. THE USE OF PORTABLE FIRE PUMPS SHALL BE AVOIDED. SHIP DOES NOT HAVE FIXED EMERGENCY FIRE PUMP.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 February 2017
Resolved 21 February 2017
Resolution: Flag survey report submitted attesting to fixed installation of emergency fire pump.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 14 January 2016
Resolved
0199 - Other (load lines) - No certificate should be extended for a period longer than one month. The vessel's CCSS Certificate was originally valid until January 4th, 2016 but received a validity extension until April 16, 2016. CCSS Code
CH 1/ Reg. 1.13.5
Action required: 705 - Other - as specified
Due 19 January 2016
Resolved 19 January 2016
Resolution: Received an Interm Certificate of Compliance for CSSC Certifcate valid until 04FEB16.