MAURY USCG vessel records Sign in
← All vessels

NEW ERA

NEW ERA is a 2011 freight ship. The Coast Guard has recorded 16 inspections since 2011, most recently in February 2026, along with 6 deficiencies and 4 operational controls.

Records from 2011 to 2026. Most recent: inspection, 24 February 2026.

Built
2011
Last inspected
24 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9510345 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A3510
1107006
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1107006

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (2011–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it43024 - Convention (Subpart B), Gross Ton
27239 - Convention (Subpart B), Net Ton
82153 - Dead Weight, Metric Ton
94350 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

24 February 2026 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8314959
4 December 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8040617
23 March 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7655664
20 March 2023 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7653635
15 March 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7651558
24 November 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7349051
3 December 2020 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7106449
2 December 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7104763
18 November 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6853767
13 December 2017 Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6319421
6 December 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6319921
8 October 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6018739
12 August 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5971160
12 August 2016 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5973766
5 June 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5889079
30 December 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4215757

Deficiency record · 6

Engineering › Steering Gear System › Feedback Unit
Issued 13 December 2017 Resolved
0936-Steering gear- Any main and auxiliary steering gear control system operable from Navigation Bridge shall be capable of being brought into operation from a position on Navigation Bridge. PSCO observed during operational test of steering system that emergency steering pump #2 continually locking preventing port movements. PSCO observed sat operation of MEG steering pump#2 under local control. 74 SOLAS (14) II-1/29.8.3 60a
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 December 2017
Resolution: Received class report from CSS stating outstanding deficiency has been rectified. The class report stated: SAT repair and operation test of #2 EMG steering gear pump.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Turbocharger
Issued 13 December 2017 Resolved
1410-Propulsion main engine- means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaks IWO SSG’s turbo oil lubricated bearing, fuel rail catchment running down engine body. Additionally, HFO strainer. 74 SOLAS (14) II-2/4.1.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: Received class report from CSS stating outstanding deficiency has been rectified.The class report stated: SAT repairs to fuel leaks, and operational test of systems.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 13 December 2017 Resolved
9900-Other (not clearly hazardous)- The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the united states must maintain a ballast water management plan that has been developed specifically for the vessel to train the person in charge on the removal of fouling organisms from vessel’s hull. PSCO observed a band of algae growth around hull, and barnacles on stern of vessel. Vessel shall remove hull growth prior to returning to the waters of the United States. Provide corrective action plan from company with concurrence from administration. 33CFR156.2050(f) 40b
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2021
Resolution: Attended vessel for PSC B exam. Vessel was last in dry dock on 1/30/21. No visible signs of marine growth on hull.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 5 June 2016 Resolved
0735-Personal Equipment Firefighting-Before ship leaves port all life saving appliances shall be in working order. PSCE observed low air alarms sounded on both fire-fighters SCBAs about 90 seconds after entering space. To additional SCBAs were brought by crew, it was also noted that they were not functioning as designed and were leaking air through various fittings-74 SOLAS(09)III/20.2 -10c
Condition: Improper/Lack of Maintenance
Due 5 June 2016
Resolved 5 June 2016
Resolution: Maintenance was conducted on SCBAs and operational tests were conducted in the presence of Port State Control examiners.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 5 June 2016 Resolved
0610-Lifeboats- Before ship leaves port all life saving appliances shall be in working order. PSCO noted free-fall life boat steering system was not functioning properly as designed. During rotation of the steering wheel by the 2nd officer the rudder was not turning with the steering wheel -74 SOLAS(09)III/20.2 - 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2016
Resolution: Vessel Provided Satisfactory NK Class Report.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, High Pressure (fuel injection)
Issued 5 June 2016 Resolved
0999-Other Safety in general- The arrangement for the storage, distribution, and utilization of oil fuel shall be such as to ensure the safety of the ship. PSCO observed unmaintained fuel oil leaks with oil soaked rage in each of the containment systems on 1 - 3 ship service diesel generators. In addition, a fluid leak was noted by one of the strainer. -74 SOLAS (09) II-2/4.2.2.2 - 10c
Condition: Improper/Lack of Maintenance
Due 5 June 2016
Resolved 5 June 2016
Resolution: Oil rags were removed and all leaks were addressed to the satisfaction of the attending Port State Control Examiner.