Records from 2016 to 2026. Most recent: inspection, 26 February 2026.
Documentation record
Registered dimensions (L × B × D)79.5 ft × 21.0 ft × 5.3 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)79.5 ft × 21.0 ft × 5.3 ft
ITC tonnagegross 120 / net 36
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2012
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it120 - Convention (Subpart B), Gross Ton
90 - Regulatory (Subpart C or D), Gross Ton
53 - Dead Weight, Ton
112 - Displacement, Ton
36 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
26 February 2026
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8317131
30 September 2025
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8244322
3 April 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8103450
10 January 2025
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8060817
20 February 2024
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7869302
28 February 2023
Excursion Permit · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7643083
18 January 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7622228
11 January 2023
Cargo Tank Internal · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7610385
8 March 2022
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7408088
11 February 2021
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7139162
20 January 2021
Drydock Exam · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7130106
18 February 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6910861
21 February 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6628740
15 January 2019
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6610634
30 January 2018
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6345947
23 October 2017
Administrative Inspection · Examination of Repairs · Construction Oversight
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6293059
25 January 2017
Cargo Tank Internal · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6076977
2 February 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5807903
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space.
Ventilation stops for engine room were inoperable from pilot house.46 CFR 181.410(10)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2025
Resolved 22 April 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 April 2025
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level.
Audible bilge alarm was not functioning with engines secured.
46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2025
Resolved 22 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2025
Resolved
An interconnected detection and alarm system must: meet UL 217 and be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d).
Vessel engine room was not interconnected to pilot house with no visual alarm. Vessel restricted to Limited
Coastwise route until compliance has been observed.
Action required: 705 - Other - as specified
Due 3 May 2025
Resolved 22 April 2025
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 April 2025
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license.
Where the station power exceeds 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a general radiotelephone operator license or higher class license.
No crew member on board had a vaild radio operator license.
47 CFR 80.159(e)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2025
Resolved 22 April 2025
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 January 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for protection against fire and necessary facilities for passengers and crew. A cable penetration for the closed-circuit security camera located within the aft A-60 fire boundary does not contain any properly fire-rated approved stuffing material, which needs to be installed.
46 CFR 177.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 2 February 2023
Resolution: Verified details on caulking tube (3M Fire Barrier Sealant) that was used to fill A-60 bulkhead penetration in the port side locker on aft deck, check SAT 835 cleared.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 January 2023
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided to indicate a high water level. Marine Inspectors (MIs) identified bilge high level indicator lights with dead bulbs for the steering gear and engine rooms when the alarms were activated.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2023
Resolved 2 February 2023
Resolution: Conducted test of bilge alarms in steering and engine room, test SAT 835 cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2023
Resolved
Where provisions are made for charging batteries, there must be natural or induced ventilation sufficient to dissipate gases generated. Two separate battery banks installed within the pilot house consoles are not ventilated. Provide an installation proposal for adequately ventilating the battery banks. 46 CFR 183.350(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 23 February 2023
Resolution: The proper battery’s /chargers have been installed and are the type designed for both spaces, that they are installed in and working as they should. The flooded lead type battery’s that were installed by mistake in the forward compartment were replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 January 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Upon entering the pilothouse, MIs personal carbon monoxide (CO) detectors alerted to the presence of CO, which may be indicative of a hydrogen off-gassing from batteries. Provide a marine electrician's report attesting to proper operation of batteries and battery charger installations. 46 CFR 183.200(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2023
Resolved 23 February 2023
Resolution: The proper battery’s /chargers have been installed and are the type designed for both spaces, that they are installed in and working as they should. The flooded lead type battery’s that were installed by mistake in the forward compartment were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2022
Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. Vessel must prove operation of ground detection meter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 18 March 2022
Resolution: Vessel rep provided video and documentary evidence of proper operation of the ground detection system.