MAURY USCG vessel records
← All vessels

MAERSK SINGAPORE

MAERSK SINGAPORE is a 2006 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in August 2026, along with 4 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 8 August 2026.

Built
2006
Last inspected
8 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 August 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9308649
9V5242
1107194
Flag
SINGAPORE
Maury page id
psix-1107194

Documentation record

Tonnage as PSIX records it93511 - Convention (Subpart B), Gross Ton
54146 - Convention (Subpart B), Net Ton
132195 - Displacement, Ton
97517 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

8 August 2026 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8450363
15 November 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8268852
14 May 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8130477
16 November 2024 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8035617
13 November 2024 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8033971
13 May 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7911135
10 November 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7822955
15 March 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7651504
12 March 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7649522
6 March 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7645992
20 August 2022 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7529901
19 December 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7370411
21 December 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7110794
16 August 2019 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6785414
3 June 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6697888
21 November 2017 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6310973
21 June 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6182493
30 December 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6064071
31 October 2016 NPV Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6032807
7 March 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5827787

Deficiency record · 4

99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 13 November 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While getting underway, PSCDO received report from VTS that the pilot on board the vessel reported not having a stern bell. 74 SOLAS (20) I/11(a) Code: 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 November 2024
Resolution: Received satisfactory class report stating all is in good working order. Please refer to the report in the "documents" tab.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2019 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed frayed and exposed electrical wire connecting No. 1 steering pump to rudder servo unit. 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 16 August 2019
Resolution: VESSEL SUBMITTED CLASS REPORT SHOWING REAPIR TO SATISFACTION OF CLASS
Fire Fighting › Fire Pumps › Suction Valve
Issued 21 June 2017 Resolved
Ship reported a leaking suction valve rendering overhaul not possible.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2017
Resolved 23 June 2017
Resolution: Fire and GS pump no.2 has been rectified and suction valve for the pump has been replaced
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 31 October 2016 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least 03 consecutive starts. A secound source of energy shall be provided for an additional three starts w/in 30 min unless manual starting can be demonstrated to be effective. Hydraulic starter for emergency generator inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2016
Resolved 30 December 2016
Resolution: Received verification from flag administration that all necessary repairs have been made.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.