Records from 2018 to 2021. Most recent: inspection, 8 December 2021.
Inspection history · 11
8 December 2021
MARPOL Annex VI Survey · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7361661
31 August 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7300921
14 July 2021
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7256009
30 May 2021
PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7206066
3 February 2020
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6901442
9 September 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6807153
19 August 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6787683
19 August 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6787692
15 August 2019
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6784708
2 July 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6733715
6 May 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6407442
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 December 2021
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the administration with a stored energy capability of at least 3 consecuive starts. A second source of energy shall be provided for an additional 3 starts within 30 mins unless manual starting can be demonstrated. Second means of starting E-gen not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2021
Resolution: Received class and flag report attesting to repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2021
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Non approved temp repair on main engine gear box and cylinder 1 stbd fwd.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 December 2021
No resolution recorded
Flammable liquid lockers shall be protected by an appropriate fire extinguishing arrangement approved by the administration. Fuel oil samples are being stored in the steering gear room, which is not protected by fixed fire protection.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 December 2021
Resolved
Escape routes shall be maintained in a safe condition, clear of obstacles. Steering gear escape door to fantail broken but fixed while onboard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 December 2021
Resolved 8 December 2021
Resolution: Fixed door while onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 30 May 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of present regulations to ensure ship in all respect will remain fit to proceed with sea without danger to the ship or person on board. PSCO observed that the fire door aft of purifying room is damaged and needs repair.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 June 2021
Resolved 31 August 2021
Resolution: Recieved photos and class report attesting to the repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 May 2021
Resolved
Suitable instruction and component spares for testing and maintenance shall be provided. PSCO observed crew using a lighter to test flame detector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2021
Resolved 14 July 2021
Resolution: Received satisfactory Class report from Lloyd's Register on acquirement of new flame detector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 February 2020
Resolved
Two ventilation covers, one on the #3 cargo hold and one on the #4 cargo hold were damaged and unable to provide an appropriate seal.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 February 2020
Resolved 10 February 2020
Resolution: Ventilation Covers were repaired and can provide appropriate seal. See documents.