Records from 2016 to 2024. Most recent: inspection, 25 September 2024.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 31 January 2011
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
15 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 15
25 September 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8008996
28 August 2024
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7991020
12 August 2024
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7979536
15 March 2023
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7651483
11 July 2022
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7505464
21 April 2022
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7435621
23 March 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7417709
9 March 2021
Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152655
10 March 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6921964
25 April 2019
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6670879
23 April 2019
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6671029
1 May 2018
Annual Inspection · Deficiency Check · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6399146
27 June 2017
Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6184443
21 March 2017
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6104836
1 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5925771
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2024
No resolution recorded
Vessel has passed the window to complete the required annual inspection and the Certificate of Inspection (COI) is no longer valid. Vessel is prohibited from operating as an inspected passenger vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 March 2022
Resolved
Provide proof of valid FCC Safety Radio telephony certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 21 April 2022
Resolution: Received proof of valid FCC SRT cert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 March 2022
Resolved
Bilge pump not secured to bilge. Provide proof of secure bilge pump
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 21 April 2022
Resolution: O/O provided proof of blige pump securely mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 March 2022
Resolved
Life ring light not operational. Provide proof of operational life ring light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 21 April 2022
Resolution: O/O provided proof of lit life ring light.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 March 2022
Resolved
No drill log book onboard vessel, no record of drills recorded for this year. Provide proof of drill log, document and conduct Fire drill and MOB drill, including during chute deployment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2022
Resolved 21 April 2022
Resolution: O/O have commenced documenting drill log.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 May 2018
Resolved
The vessel is required to have a valid Certificate of Documentation (COD). The vessel's Certificate of Documentation (COD)expired on 31AUG2017. The vessel is required to provide a valid Certificate of Documentation (COD)prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2018
Resolved 4 May 2018
Resolution: corrected.
Fire Fighting › Fire Bucket › Capacity
Issued 1 May 2018
Resolved
The vessel is required to have (3) 2.5 gallon fire buckets on board. The vessel has (3) 2 gallon fire buckets on board. The vessel is required to provide (3) 2.5 gallon fire buckets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 9 May 2018
Resolution: The vessel owner provided 3x 2.5 gal fire buckets; all SAT.
Accommodation/Occupational Safety › Ventilation › General
Issued 27 June 2017
Resolved
Properly mount engineroom ventilation fan
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2017
Resolved 27 June 2017
Resolution: Vessel mounted fan
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 June 2017
Resolved
Replace identified retroreflective tape on 2 child lifejackets.
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Resolution: Vessel replaced retro tape
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2017
Resolved
Provide valid asprin and burn gel
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Resolution: Vessel provided asprin and burn gel
Engineering › Bilge Water Management System › Interface Detector
Issued 27 June 2017
Resolved
Repair E/R bilge alarm indicating light
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Resolution: Vessel repaired indicating light
Construction/Loadline › Structures › Scuttle
Issued 27 June 2017
Resolved
Repair fwd hatch
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 10 July 2017
Resolution: Vessel repaired fwd hatch
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 June 2017
Resolved
Provide proof of user fee payment
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 27 June 2017
Resolution: Vessel provided proof of payment
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 July 2016
Resolved
Complete a credit annual exam. Vessel is overdue for annual exam as of 20May2016.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2016
Resolved 7 July 2016
Resolution: Vessel recieved annual exam
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 1 July 2016
Resolved
Replace starter relay
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 14 July 2016
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 1 July 2016
Resolved
Provide EPIRB registaration to NOAA
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 14 July 2016
Resolution: Register EPIRB
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 July 2016
Resolved
Repair STBD green running light
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 14 July 2016
Resolution: Repair green running light
Communications › Radio Communications › VHF Radiotelephone
Issued 1 July 2016
Resolved
Provide FCC operators License for Captain
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 14 July 2016
Resolution: FCC license was provided